ORELAPIRON LaboratoriesNELAP Accredited Laboratory

ORELAP Cert No. 4092-002
OLCC No. 1002158CD2E

Marijuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 4092-002 Test Certificate #: 98720-001
Client Name, Sample Details

John Mutter
Livingston, TX 77391
Sample: Coconut Oil
Type: Infused Product
Method: FE04E-OR4 HPLC1100-OR1

Test Conditions

Prepsheet ID#: P-171013B
Scale: XS205-OR1
Temp: 20 °C
Baro Pressure: 1009 hPa
Analyst: HRM
Technician: HRM

Sample ID#: 98720

Harvest/Process Date: 10/09/2017
Serving Size (g): 14.18
Date Received: 10/09/2017
Test Date: 10/13/2017

Sample #98720
Sample #98720 Sample #98720
Test
Compounds
CBDV CBDA CBD CBC CBG CBN THC THCA THCV   AVG CBD Decarb. % THC Decarb. %
Amount 0.24 mg/g 0.01 mg/g 5.09 mg/g 0.26 mg/g 0.08 mg/g 0.02 mg/g 0.21 mg/g 0.01 mg/g 0.01 mg/g THC 0.21 mg/g 100 95
LOQ 0.006 mg/g 0.006 mg/g 0.006 mg/g 0.006 mg/g 0.006 mg/g 0.006 mg/g 0.006 mg/g 0.006 mg/g 0.006 mg/g CBD 5.09 mg/g - -
Amount per Serving~ 3.40 mg/srv 0.14 mg/srv 72.18 mg/srv 3.69 mg/srv 1.13 mg/srv 0.28 mg/srv 2.98 mg/srv 0.14 mg/srv 0.14 mg/srv - Serving Size~ (g): 14.18 g -
Uncertainty 4.26% RPD 0.00% RPD 2.56% RPD 0.00% RPD 0.00% RPD 0.00% RPD 102.44% RPD 10.25% RPD 0.00% RPD - - - -

Serving size = 1 tablespoon = 14.18 grams

LOQ = Limit of Quantitation

RPD is relative percent difference between the LCS and LCS duplicate.

%RPD = Relative Percent Difference; Min. Value = Minimum Detectable Amount, CFU = Colony Forming Units, N/D = Not Detected

*** Designated tests that use the method FE-45.

Total CBD or THC is the calculated sum of CBD or THC and the amount of CBD or THC derived from CBDA or THCA, respectively. These values are calculated by adding a molar correction factor of 0.877 to the CBDA or THCA value.

THC and CBD Decarb. % referes to the percentage of THC or CBD relative to THCA or CBDA, respectively

Avg. is the calculated average of total CBD or total THC for all increments tested.

This sample has not been tested according to OAR 333-007. These results should therefore be used for research and development or quality control purposes only.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Joseph Rutowski Iron laboratories Joseph Rutowski

Iron Labs Oregon complies with 2009 TNI Environmental Laboratory Standards.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401

Page 1 of 1

ORELAPIRON LaboratoriesNELAP Accredited Laboratory

ORELAP Cert No. 4092-002
OLCC No. 1002158CD2E

QC Report

Testing Accreditation #: 4092-002 Test Certificate #: 98720-001
Client Name, Sample Details

John Mutter
Livingston, TX 77391
Sample: Coconut Oil
Type: Infused Product
Method: FE04E-OR4 HPLC1100-OR1

Test Conditions

Prepsheet ID#: P-171013B
Scale: XS205-OR1
Temp: 20 °C
Baro Pressure: 1009 hPa
Analyst: HRM
Technician: HRM

Sample ID#: 98720

Harvest/Process Date: 10/09/2017
Serving Size (g): 14.18
Date Received: 10/09/2017
Test Date: 10/13/2017

Sample #98720
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD Relative Percent Difference (%) QC Flag
Cannabidivarin (CBDV) N.D. 5.79 5.65 97.58 5.96 102.94 5.34%
Cannabidiolic Acid (CBDA) N.D. 5.53 5.3 95.84 5.65 102.17 6.39%
Cannabigerol (CBG) N.D. 5.34 5.03 94.19 5.38 100.75 6.72%
Cannabidiol (CBD) N.D. 5.09 4.81 94.50 5.14 100.98 6.63%
Δ9-Tetrahydrocannabivarin (THCV) N.D. 5.55 5.24 94.41 5 90.09 4.69%
Cannabinol (CBN) N.D. 4.92 4.7 95.53 4.93 100.20 4.78%
Δ9-Tetrahydrocannabinol (THC) N.D. 5.07 5.25 103.55 5.06 99.80 3.69%
Cannabichromene (CBC) N.D. 5.7 5.85 102.63 5.76 101.05 1.55%
Tetrahydrocannabinolic acid (THCA) N.D. 4.96 5.95 119.96 5.37 108.27 10.25%

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

This sample has not been tested according to OAR 333-007. These results should therefore be used for research and development or quality control purposes only.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Joseph Rutowski Iron laboratories Joseph Rutowski

Iron Labs Oregon complies with 2009 TNI Environmental Laboratory Standards.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401