IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

Marihuana Potency Analysis by
Gas Chromatography

Testing Accreditation #: 77802 Test Certificate #: 95364-001
Client Name, Sample Details

Green River Meds
Detroit, MI 48219
Sample: Stink Bomb
Type: Flower
Method: FE03 GC6890-1

Test Conditions

Scale: XS205-MI1
Temp: 21.6 °C
Baro Pressure: 980.8 hPa
Analyst: JCM
Technician: JCM

Sample ID#: 95364

Harvest/Process Date: 06/21/2017
Serving Size (g): 1.25
Date Received: 06/20/2017
Test Date: 06/21/2017
Valid Through: 06/22/2018
Report Issued: 06/22/2017

Sample #95364
Sample #95364 Sample #95364
Test
Compounds
CBDV THCV CBC CBD Δ8 THC Δ9 THC CBG CBN TOTAL
Amount N/D 0.7 0.2 0.1 N/D 19.1 0.5 N/D 20.6%
Min. Value 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% -
Uncertainty† ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD -

†Uncertainty measurement is for the test procedure and the instrument used; and is calculated in accordance with the ISO "Guide of Uncertainty in Measurement" (GUM) Test Results and uncertainty are only representative of the sample submit to our laboratory. Uncertainty does not account for any uncertainty in the sampling. The measurement of uncertainty is the expanded uncertainty and is an estimate of uncertainty calculated with normal distribution and a coverage factor of 2 (K=2) to approximate a 95% confidence level. 

%RSD = Relative Standard Deviation; Min. Value = Minimum Detectable Amount, CFU = Colony Forming Units

N/D designates a value that is not detected above the methods Limit of quantitation (min. value)

Values are not adjusted for moisture content.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Makenzie Hyman Iron laboratories Makenzie Hyman

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 2

IRON Laboratories

Bio Analysis by
Microscopic Visual Inspection

Test Certificate #: 95364-001
Client Name, Sample Details

Green River Meds
Detroit, MI 48219
Sample: Stink Bomb
Type: Flower
Method: FE02 Microscope Dissection

Test Conditions

Analyst: ACR
Technician: ACR

Sample ID#: 95364

Harvest/Process Date: 06/21/2017
Serving Size (g): 1.25
Date Received: 06/20/2017
Test Date: 06/21/2017
Valid Through: 06/21/2018
Report Issued: 06/21/2017

Sample #95364
Sample #95364 Sample #95364
Impurities: Not Detected
Molds: No Types: N/A
Pests: No Types: N/A
Anthers: No
Detritus: No
Fibers: No
Hair: No
Mature Seeds: No
Premature Seeds: No
Unidentified Foliar Spray: No
Other Impurities: No
*Moisture 8

The gland heads range from small to medium in size and are moderately abundant. Slightly more of them are clear than milky with a A moderate amount of the trichomes are damaged and degrading. A few of the trichomes are reduced due to stress.

*Moisture is not part of the accredited scope of Iron Laboratories.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Jon Markey Iron laboratories Jon Markey

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390