ORELAPIRON LaboratoriesNELAP Accredited Laboratory

ORELAP Cert No. 4092-001
OLCC No. 1002158CD2E

Marijuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 4091 Test Certificate #: 93809-001
Client Name, Sample Details

45th Parallel Farms LLC
Dallas, OR 97338
Sample: Northern Wreck Keif
License: 010-100164183CE
Type: Flower
Method: FE04N-OR1 HPLC1100-OR1
Metrc Test Pkg#: 1A4010300000DAD000000655
***Water Activity: 0.42
***Moisture: 13.525%

Test Conditions

Scale: XS205-OR1
Temp: 19.6 °C
Baro Pressure: 999.6 hPa
Analyst: HRM
Technician: HRM

Sample ID#: 93809

Harvest/Process Date: 10/22/2016
Serving Size (g): 53273
Date Received: 05/12/2017
Test Date: 05/16/2017

Sample #93809
Sample #93809 Sample #93809
Test
Compounds
CBDA CBD CBC CBG CBN THC THCA THCV   Calc. Max Act.
Amount 0.1 N/D 0.1 0.2 0.2 3.7 57.2 N/D CBD N/A 0%
LOQ 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% THC 53.8644% 6%
Uncertainty† ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD Totals: 0.0% -

LOQ = Limit of Quantitation

RPD is relative percent difference between the LCS and LCS duplicate.

%RPD = Relative Percent Difference; Min. Value = Minimum Detectable Amount, CFU = Colony Forming Units, N/D = Not Detected

Calc. Max. is the calculated sum of CBD or THC and the amount of CBD or THC derived from CBDA or THCA; respectively .These values are calculated by applying a molar correction factor of 0.877 to the CBDA or THCA value.

*** Designated tests that use the method FE-45.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Joseph Rutowski Iron laboratories Joseph Rutowski

Iron Labs Oregon complies with 2009 TNI Environmental Laboratory Standards.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401