IRON Laboratories

Marihuana Potency Analysis by
Gas Chromatography

Test Certificate #: 92346-001
Client Name, Sample Details

Mitten Green Wellness
Sterling Heights , MI 48313
Sample: Star Tonic
Type: Medical Compliant Flower
Method: FE03 GC6890-1

Test Conditions

Scale: XS205-MI1
Temp: 21.2 °C
Baro Pressure: 969.5 hPa
Analyst: JCM
Technician: JCM

Sample ID#: 92346

Harvest/Process Date: 04/03/2017
Serving Size (g): 51944
Date Received: 03/31/2017
Test Date: 03/31/2017
Valid Through: 03/31/2018
Report Issued: 03/31/2017

Sample #92346
Sample #92346 Sample #92346
Test
Compounds
CBDV THCV CBC CBD Δ8 THC Δ9 THC CBG CBN TOTAL
Amount 0.1 0.3 2.3 35.8 0.3 27.0 1.4 0.1 67.3%
Min. Value 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% -
Uncertainty† ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD -

†Uncertainty measurement is for the test procedure and the instrument used; and is calculated in accordance with the ISO "Guide of Uncertainty in Measurement" (GUM) Test Results and uncertainty are only representative of the sample submit to our laboratory. Uncertainty does not account for any uncertainty in the sampling. The measurement of uncertainty is the expanded uncertainty and is an estimate of uncertainty calculated with normal distribution and a coverage factor of 2 (K=2) to approximate a 95% confidence level. 

%RSD = Relative Standard Deviation; Min. Value = Minimum Detectable Amount, CFU = Colony Forming Units

N/D designates a value that is not detected above the methods Limit of quantitation (min. value)

Values are not adjusted for moisture content.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Makenzie Hyman Iron laboratories Makenzie Hyman

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 3

IRON Laboratories

Terpene Report by
Mass Spectrometer

Test Certificate #: 92346-001
Client Name, Sample Details

Mitten Green Wellness
Sterling Heights , MI 48313
Sample: Star Tonic
Type: Medical Compliant Flower
Method: FE03 HP5890-2

Test Conditions

Scale: XS205-MI1
Temp: 21.2 °C
Baro Pressure: 969.5 hPa
Analyst: MEH
Technician: MEH

Sample ID#: 92346

Harvest/Process Date: 04/03/2017
Serving Size (g): 51944
Date Received: 03/31/2017
Report Issued: 04/03/2017

Sample #92346

Mono Terpenes

Weight Percentage Dry Matter (wt/wt%)

α-Pinene:

0.270 %

β-Ocimene:

0.030 %

Camphene:

0.020 %

Eucalyptol (1,8-Cineol):

N/D

Sabinene:

N/D

γ-Terpinene:

N/D

Myrcene:

0.300 %

α-Terpinolene:

0.080 %

β-Pinene:

0.150 %

Linalool:

0.170 %

∆3-Carene:

N/D

Fenchone:

N/D

α-Terpinene:

0.010 %

Fenchol:

0.050 %

Ocimene:

0.010 %

Isopulegol:

N/D

Limonene:

0.140 %

Geraniol:

N/D

4-Cymene:

N/D

Sequi Terpenes

Weight Percentage Dry Matter (wt/wt%)

β-Caryophyllene:

0.890 %

α-Humulene:

0.270 %

Nerolidol 1:

0.120 %

Nerolidol 2:

0.040 %

Guaiol:

0.100 %

Caryophyllene Oxide:

0.030 %

α-Bisabolol:

0.150 %

Other Terpenes

Total: 2.830%
(not included in the calculated total): a-phellandrene - 0.02%; a-terpineol - 0.06%; valencene - 0.02%

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Jon Markey Iron laboratories Jon Markey

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 3

IRON Laboratories

Bio Analysis by
Gas Chromatography

Test Certificate #: 92346-001
Client Name, Sample Details

Mitten Green Wellness
Sterling Heights , MI 48313
Sample: Star Tonic
Type: Medical Compliant Flower
Method: FE03 GC6890-1

Test Conditions

Scale: XS205-MI1
Temp: 21.2 °C
Baro Pressure: 969.5 hPa
Analyst: JCM
Technician: JCM

Sample ID#: 92346

Harvest/Process Date: 04/03/2017
Serving Size (g): 51944
Date Received: 03/31/2017
Test Date: 03/31/2017
Valid Through: 03/31/2018
Report Issued: 03/31/2017

Sample #92346
Sample #92346 Sample #92346
Impurities: Not Detected
Molds: No Types: N/A
Pests: No Types: N/A
Anthers: No
Detritus: No
Fibers: No
Hair: No
Mature Seeds: No
Premature Seeds: No
Unidentified Foliar Spray: No
Other Impurities: No
*Moisture -

*Moisture is not part of the accredited scope of Iron Laboratories.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 3 of 3