IRON Laboratories

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Test Certificate #: 89653-001
Client Name, Sample Details

Midnight
Redford Twp, MI 48239
Sample: Canna Butter
Type: Infused Product
Method: FE04 HPLC1100-1

Test Conditions

Scale: XS205-MI1
Temp: 21.1 °C
Baro Pressure: 970.8 hPa
Analyst: JCM
Technician: JCM

Sample ID#: 89653

Harvest/Process Date: 01/16/2017
Serving Size (g): 14
Date Received: 01/13/2017
Test Date: 01/16/2017
Valid Through: 01/16/2018
Report Issued: 01/13/2017

Sample #89653
Sample #89653 Sample #89653
Test
Compounds
CBDA CBD CBN THC THCA TOTAL CBD Act. THC Act.
Amount N/D N/D 0.5 1.6 0.5 2.6 N/A 76%
Min. Value 0.1 mg/g 0.1 mg/g 0.1 mg/g 0.1 mg/g 0.1 mg/g - - -
Amount per Serving~ N/D N/D 7.0 mg/srv 22.4 mg/srv 7.0 mg/srv 36.4 mg/srv Serving Size~ (g): 14.00 g
Uncertainty† ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD - - -

†Uncertainty measurement is for the test procedure and the instrument used; and is calculated in accordance with the ISO "Guide of Uncertainty in Measurement" (GUM) Test Results and uncertainty are only representative of the sample submit to our laboratory. Uncertainty does not account for any uncertainty in the sampling. The measurement of uncertainty is the expanded uncertainty and is an estimate of uncertainty calculated with normal distribution and a coverage factor of 2 (K=2) to approximate a 95% confidence level. 

%RSD = Relative Standard Deviation; Min. Value = Minimum Detectable Amount, CFU = Colony Forming Units

N/D designates a value that is not detected above the methods Limit of quantitation (min. value)

Values are not adjusted for moisture content.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Makenzie Hyman Iron laboratories Makenzie Hyman

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 2

IRON Laboratories

Bio Analysis by
High Performance Liquid Chromatography

Test Certificate #: 89653-001
Client Name, Sample Details

Midnight
Redford Twp, MI 48239
Sample: Canna Butter
Type: Infused Product
Method: FE04 HPLC1100-1

Test Conditions

Scale: XS205-MI1
Temp: 21.1 °C
Baro Pressure: 970.8 hPa
Analyst: JCM
Technician: JCM

Sample ID#: 89653

Harvest/Process Date: 01/16/2017
Serving Size (g): 14
Date Received: 01/13/2017
Test Date: 01/16/2017
Valid Through: 01/16/2018
Report Issued: 01/13/2017

Sample #89653
Sample #89653 Sample #89653
Impurities: Not Detected
Molds: No Types: N/A
Pests: No Types: N/A
Anthers: No
Detritus: No
Fibers: No
Hair: No
Mature Seeds: No
Premature Seeds: No
Unidentified Foliar Spray: No
Other Impurities: No
*Moisture -

*Moisture is not part of the accredited scope of Iron Laboratories.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 2