IRON Laboratories

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Test Certificate #: 75273-001
Client Name, Sample Details

Ryan Williamson
Traverse City, MI 48506
Sample: Bud White's Wookie Cookie
Type: Flower
Method: FE04N HPLC1100-1

Test Conditions

Scale: AB200
Temp: 20.5 °C
Baro Pressure: 970 hPa
Analyst: MEH
Technician: MEH

Sample ID#: 75273

Harvest/Process Date: 12/19/2015
Serving Size (g): 1.57
Date Received: 12/22/2015
Test Date: 12/23/2015
Valid Through: 12/23/2016
Report Issued: 12/19/2015

Sample #75273
Sample #75273 Sample #75273
Test
Compounds
CBDA CBD CBN THC THCA   Calc. Max Act.
Amount 0.6 N/D N/D 1.4 29.3 CBD 0.5262% 0%
Min. Value 0.1% 0.1% 0.1% 0.1% 0.1% THC 27.0961% 5%
Uncertainty† ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD Totals: 27.6% -

†Uncertainty measurement is for the test procedure and the instrument used; and is calculated in accordance with the ISO "Guide of Uncertainty in Measurement" (GUM) Test Results and uncertainty are only representative of the sample submit to our laboratory. Uncertainty does not account for any uncertainty in the sampling. The measurement of uncertainty is the expanded uncertainty and is an estimate of uncertainty calculated with normal distribution and a coverage factor of 2 (K=2) to approximate a 95% confidence level. 

%RSD = Relative Standard Deviation; Min. Value = Minimum Detectable Amount, CFU = Colony Forming Units

Calc. Max. is the calculated sum of CBD or THC and the amount of CBD or THC derived from CBDA or THCA; respectively .These values are calculated by applying a molar correction factor of 0.877 to the CBDA or THCA value.

To convert mg/g to percent (wt/wt%), divide your mg/g value by 10

N/D designates a value that is not detected above the methods Limit of quantitation (min. value)

Values are not adjusted for moisture content.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Makenzie Hyman Iron laboratories Makenzie Hyman

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 2

IRON Laboratories

Bio Analysis by
High Performance Liquid Chromatography

Test Certificate #: 75273-001
Client Name, Sample Details

Ryan Williamson
Traverse City, MI 48506
Sample: Bud White's Wookie Cookie
Type: Flower
Method: FE04N HPLC1100-1

Test Conditions

Scale: AB200
Temp: 20.5 °C
Baro Pressure: 970 hPa
Analyst: MEH
Technician: MEH

Sample ID#: 75273

Harvest/Process Date: 12/19/2015
Serving Size (g): 1.57
Date Received: 12/22/2015
Test Date: 12/23/2015
Valid Through: 12/23/2016
Report Issued: 12/19/2015

Sample #75273
Sample #75273 Sample #75273
Impurities: Not Detected
Molds: No Types: N/A
Pests: No Types: N/A
Anthers: No
Detritus: No
Fibers: No
Hair: No
Mature Seeds: No
Premature Seeds: No
Unidentified Foliar Spray: No
Other Impurities: No
*Moisture 7

*Moisture is not part of the accredited scope of Iron Laboratories.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 2