IRON Laboratories

Marihuana Potency Analysis by
Gas Chromatography

Test Certificate #: 73587-001
Client Name, Sample Details

The House and Company
Detroit, MI 48219
Sample: Hog OG
Type: Flower
Method: FE03 GC6890-1

Test Conditions

Scale: AB-200
Temp: 20 °C
Baro Pressure: 990 hPa
Analyst: JCM
Technician: JCM

Sample ID#: 73587

Harvest/Process Date: 11/09/2015
Serving Size (g): 1.79
Date Received: 11/10/2015
Test Date: 11/10/2015
Valid Through: 11/10/2016
Report Issued: 11/09/2015

Sample #73587
Sample #73587 Sample #73587
Test
Compounds
CBDV THCV CBC CBD Δ8 THC Δ9 THC CBG CBN TOTAL
Amount N/D 0.1 0.6 0.1 N/D 19.2 0.7 N/D 20.7%
Min. Value 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% -
Uncertainty† ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD -

†Uncertainty measurement is for the test procedure and the instrument used; and is calculated in accordance with the ISO "Guide of Uncertainty in Measurement" (GUM) Test Results and uncertainty are only representative of the sample submit to our laboratory. Uncertainty does not account for any uncertainty in the sampling. The measurement of uncertainty is the expanded uncertainty and is an estimate of uncertainty calculated with normal distribution and a coverage factor of 2 (K=2) to approximate a 95% confidence level. 

%RSD = Relative Standard Deviation; Min. Value = Minimum Detectable Amount, CFU = Colony Forming Units

N/D designates a value that is not detected above the methods Limit of quantitation (min. value)

Values are not adjusted for moisture content.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Makenzie Hyman Iron laboratories Makenzie Hyman

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 2

IRON Laboratories

Bio Analysis by
Gas Chromatography

Test Certificate #: 73587-001
Client Name, Sample Details

The House and Company
Detroit, MI 48219
Sample: Hog OG
Type: Flower
Method: FE03 GC6890-1

Test Conditions

Scale: AB-200
Temp: 20 °C
Baro Pressure: 990 hPa
Analyst: JCM
Technician: JCM

Sample ID#: 73587

Harvest/Process Date: 11/09/2015
Serving Size (g): 1.79
Date Received: 11/10/2015
Test Date: 11/10/2015
Valid Through: 11/10/2016
Report Issued: 11/09/2015

Sample #73587
Sample #73587 Sample #73587
Impurities: Detected
photo1: Two species of fungi growing on the stigma SEE ATTACHED FOR ADDITIONAL PHOTOS: photo2: Another species of fungi growing all along the stigma, and hyphae spreading photo3: Pest (unknown) NOTE: 3+ species of fungi identified on multiple locations of the flower at multiple nodes NOTE: Pests
Molds: Yes Types: Hyphae
Pests: Yes Types: N/A
Anthers: No
Detritus: No
Fibers: No
Hair: No
Mature Seeds: No
Premature Seeds: No
Unidentified Foliar Spray: No
Other Impurities: No
*Moisture 8

*Moisture is not part of the accredited scope of Iron Laboratories.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 2