IRON Laboratories

Marihuana Potency Analysis by
Gas Chromatography

Test Certificate #: 72656-001
Client Name, Sample Details

Mi Cannabis Critiques
sterling heights, MI 48313
Sample: Granddaddy Purps F2
Type: Flower
Method: FE03 GC6890-1

Test Conditions

Scale: Balance AB-200
Temp: 20.3 °C
Baro Pressure: 986 hPa
Analyst: JCM
Technician: JCM

Sample ID#: 72656

Harvest/Process Date: 10/15/2015
Serving Size (g): 1.61
Date Received: 10/19/2015
Test Date: 10/19/2015
Valid Through: 10/19/2016
Report Issued: 10/15/2015

Sample #72656
Sample #72656 Sample #72656
Test
Compounds
CBDV THCV CBC CBD Δ8 THC Δ9 THC CBG CBN TOTAL
Amount N/D 0.1 0.3 0.1 N/D 18.9 0.7 N/D 20.1%
Min. Value 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% 0.1% -
Uncertainty† ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD -

†Uncertainty measurement is for the test procedure and the instrument used; and is calculated in accordance with the ISO "Guide of Uncertainty in Measurement" (GUM) Test Results and uncertainty are only representative of the sample submit to our laboratory. Uncertainty does not account for any uncertainty in the sampling. The measurement of uncertainty is the expanded uncertainty and is an estimate of uncertainty calculated with normal distribution and a coverage factor of 2 (K=2) to approximate a 95% confidence level. 

%RSD = Relative Standard Deviation; Min. Value = Minimum Detectable Amount, CFU = Colony Forming Units

N/D designates a value that is not detected above the methods Limit of quantitation (min. value)

Values are not adjusted for moisture content.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Makenzie Hyman Iron laboratories Makenzie Hyman

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 2

IRON Laboratories

Bio Analysis by
Gas Chromatography

Test Certificate #: 72656-001
Client Name, Sample Details

Mi Cannabis Critiques
sterling heights, MI 48313
Sample: Granddaddy Purps F2
Type: Flower
Method: FE03 GC6890-1

Test Conditions

Scale: Balance AB-200
Temp: 20.3 °C
Baro Pressure: 986 hPa
Analyst: JCM
Technician: JCM

Sample ID#: 72656

Harvest/Process Date: 10/15/2015
Serving Size (g): 1.61
Date Received: 10/19/2015
Test Date: 10/19/2015
Valid Through: 10/19/2016
Report Issued: 10/15/2015

Sample #72656
Sample #72656 Sample #72656
Impurities: Detected
photo1: 3+ species of sporulating fungi in this photo as well as mycelia. The white tufts are one species, then there are both black and brown dots that are separate types of spores SEE ATTACHED FOR ADDITIONAL PHOTOS: photo2: Fungal spores photo3: Verticillium species (fungal spores) NOTE: 3+ SPECIES OF FUNGI IDENTIFIED ON SAMPLE = SEVERE
Molds: Yes Types: Hyphae, Mildew
Pests: No Types: N/A
Anthers: No
Detritus: No
Fibers: No
Hair: No
Mature Seeds: No
Premature Seeds: No
Unidentified Foliar Spray: No
Other Impurities: No
*Moisture 11

*Moisture is not part of the accredited scope of Iron Laboratories.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 2