IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 77802 Test Certificate #: 154046-001
Client Name, Sample Details

Greenroom Gardens LLC AU-G-C-000910
Muskegon, MI 49441
Sample: Banana Runtz
License: AU-G-C-000910
Type: Adult Use Flower
Method: FE04U12 HPLC-UV
Metrc Test Pkg#: 1A4050300032E11000001231
Metrc Source Pkg#: 1A4050300032E11000001230
***Water Activity: 0.59

Test Conditions

Prepsheet ID#: MIP250314b
Scale: XS205-MI1
Temp: 23.1 °C
Baro Pressure: 980.3 hPa
Analyst: MEH
Technician: ARH

Sample ID#: 154046

Harvest/Process Date: 03/17/2025
Serving Size (g): 1
Date Received: 03/17/2025
Test Date: 03/14/2025
Valid Through: 03/15/2026
Report Issued: 03/18/2025

Sample #154046
Sample #154046 Sample #154046
Test
Compounds
Δ9-THC THCA Δ8-THC CBD CBDA CBG CBGA CBN CBC CBL THCV CBDV Total
Cannabinoids*
Total THC Total CBD Calc Max Total
Cannabinoids*
Amount (%) 1.5 26.6 N/D N/D 0.1 0.1 0.3 N/D N/D N/D N/D N/D 28.6 24.8 0.1 25.3
Amount (mg/g) 15.3 265.7 N/D N/D 0.9 0.8 2.98 N/D N/D N/D N/D N/D 285.68 248.3 0.8 252.5
Amount per Serving (mg) 15.3 265.7 N/D N/D 0.9 0.8 2.98 N/D N/D N/D N/D N/D 285.7 Serving Size~ (g): 1.0
LOQ (mg/g) 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78 0.78   %Decarb. THC CBD
±%RPD 3.17% 3.90% 0.83% 2.42% 2.56% 5.30% 2.53% 4.19% 3.83% 4.64% 3.37% 6.65% 5 0%

Sample passes for water activity (sample fails if Aw>0.65). Water activity is measured utilizing SOP FE-45 (water activity meter).

LOQ = Limit of Quantitation; %RPD = Relative Percent Deviation; %RSD = Relative Standard Deviation; N/D = Not Detected

*Designates values that are not currently included in the accredited scope of Iron Laboratories.

*** Designates tests that use the method FE-45. FE-45 is performed using AOAC 966.02 and 32.004-32.009.

FE-45 has relative expanded (k=2) uncertainties of 1.098% for moisture, 1.754% for water activity for unprocessed plant materials, and 13.102% for water activity for infused products.

Vitamin E acetate analysis has a relative expanded (k=2) uncertainty of 18.614%.

Total THC and CBD is the calculated sum of Δ9-THC and Δ8-THC or CBD plus the amount of THC or CBD derived from THCA or CBDA, respectively.

These values are calculated by applying a molar correction factor of 0.877 to the THCA or the CBDA value.

Calc Max Total Cannabinoids is the sum of Total THC, Total CBD, CBN, Total CBG, CBC, THCV, CBDV, and CBL.

Total CBG is calculated as CBG plus CBGA*0.878 (the molar correction factor for CBGA to CBG conversion).

%Decarb. THC and CBD refer to the percentage of Δ9-THC or CBD relative to THCA or CBDA, respectively.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 154046-001
Client Name, Sample Details

Greenroom Gardens LLC AU-G-C-000910
Muskegon, MI 49441
Sample: Banana Runtz
License: AU-G-C-000910
Type: Adult Use Flower
Method: FE04U12 HPLC-UV
Metrc Test Pkg#: 1A4050300032E11000001231
Metrc Source Pkg#: 1A4050300032E11000001230
***Water Activity: 0.59

Test Conditions

Prepsheet ID#: MIP250314b
Scale: XS205-MI1
Temp: 23.1 °C
Baro Pressure: 980.3 hPa
Analyst: MEH
Technician: ARH

Sample ID#: 154046

Harvest/Process Date: 03/17/2025
Serving Size (g): 1
Date Received: 03/17/2025
Test Date: 03/14/2025
Valid Through: 03/15/2026
Report Issued: 03/18/2025

Sample #154046
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD Relative Percent Difference (%) QC Flag
Δ9-THC 0 5.37288 5.61651 104.53 5.44125 101.27 3.17%
THCA 0 4.95397 5.12779 103.51 4.93143 99.55 3.90%
Δ8-THC 0 5.28643 5.50429 104.12 5.45877 103.26 0.83%
CBD 0 5.2838 5.49785 104.05 5.36645 101.56 2.42%
CBDA 0 5.06811 5.23359 103.27 5.10138 100.66 2.56%
CBG 0 5.24731 5.4598 104.05 5.17768 98.67 5.30%
CBGA 0 5.0397 5.19927 103.17 5.06933 100.59 2.53%
CBN 0 5.26831 5.47153 103.86 5.24713 99.60 4.19%
CBC 0 5.33221 5.53528 103.81 5.32743 99.91 3.83%
CBCA N/A 0 0 0.00 0 0.00 0% N/A
CBL 0 5.27614 5.45216 103.34 5.20505 98.65 4.64%
THCV 0 5.26472 5.47892 104.07 5.29708 100.61 3.37%
CBDV 0 5.20557 5.6105 107.78 5.24952 100.84 6.65%

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Pesticide Analysis by
Mass Spectrometer

Testing Accreditation #: 77802 Test Certificate #: 154046-001
Client Name, Sample Details

Greenroom Gardens LLC AU-G-C-000910
Muskegon, MI 49441
Sample: Banana Runtz
License: AU-G-C-000910
Type: Adult Use Flower
Method: FE-52 (EN 15662 & AOAC 2007.01)
Metrc Test Pkg#: 1A4050300032E11000001231
Metrc Source Pkg#: 1A4050300032E11000001230

Test Conditions

Prepsheet ID#: MIPS250314b
Scale: XS205-MI1
Temp: 23.8 °C
Baro PE: 978.1 hPa
Analyst: OSB
Technician: OSB

Sample ID#: 154046

Harvest/Process Date: 03/17/2025
Serving Size (g): 1
Date Received: 03/17/2025
Test Date: 03/14/2025
Valid Through: 03/14/2026
Report Issued: 03/17/2025

Sample #154046
Compound MRL (µg/g) LOD (µg/g) Status (µg/g)   Compound MRL (µg/g) LOD (µg/g) Status (µg/g)
Aldicarb 0.400 0.200 Pass/<LOD Abamectin**** 0.500 0.250 Pass/<LOD
Acephate 0.400 0.200 Pass/<LOD Acequinocyl 2.000 1.000 Pass/<LOD
Acetamiprid 0.200 0.100 Pass/<LOD Azoxystrobin 0.200 0.100 Pass/<LOD
Bifenazate 0.200 0.100 Pass/<LOD Bifenthrin 0.200 0.100 Pass/<LOD
Boscalid 0.400 0.200 Pass/<LOD Carbaryl 0.200 0.100 Pass/<LOD
Carbofuran 0.200 0.100 Pass/<LOD Chlorantraniliprole 0.200 0.100 Pass/<LOD
Chlorfenapyr 1.000 0.500 Pass/<LOD Chlorpyrifos 0.200 0.100 Pass/<LOD
Clofentezine 0.200 0.100 Pass/<LOD Cyfluthrin** 1.000 0.500 Pass/<LOD
Cypermethrin*** 1.000 0.500 Pass/<LOD Daminozide 1.000 0.500 Pass/<LOD
DDVP (Dichlorvos) 1.000 0.500 Pass/<LOD Diazinon 0.200 0.100 Pass/<LOD
Dimethoate 0.200 0.100 Pass/<LOD Ethoprophos 0.200 0.100 Pass/<LOD
Etofenprox 0.400 0.200 Pass/<LOD Etoxazole 0.200 0.100 Pass/<LOD
Fenoxycarb 0.200 0.100 Pass/<LOD Fenpyroximate 0.400 0.200 Pass/<LOD
Fipronil 0.400 0.200 Pass/<LOD Flonicamid 1.000 0.500 Pass/<LOD
Fludioxonil 0.400 0.200 Pass/<LOD Hexythiazox 1.000 0.500 Pass/<LOD
Imazalil 0.200 0.100 Pass/<LOD Imidacloprid 0.400 0.200 Pass/<LOD
Kresoxim Methyl 0.400 0.200 Pass/<LOD Malathion 0.200 0.100 Pass/<LOD
Metalaxyl 0.200 0.100 Pass/<LOD Methiocarb 0.200 0.100 Pass/<LOD
Methomyl 0.400 0.200 Pass/<LOD Methyl Parathion 0.200 0.100 Pass/<LOD
MGK-264‡ 0.200 0.100 Pass/<LOD Myclobutanil 0.200 0.100 Pass/<LOD
Naled 0.500 0.250 Pass/<LOD Oxamyl 1.000 0.500 Pass/<LOD
Paclobutrazol 0.400 0.200 Pass/<LOD Permethrins† 0.200 0.100 Pass/<LOD
Phosmet 0.200 0.100 Pass/<LOD Piperonyl Butoxide 100.000 1.900 Not Tested
Prallethrin 0.200 0.100 Pass/<LOD Propiconazole 0.400 0.200 Pass/<LOD
Propoxur 0.200 0.100 Pass/<LOD Pyrethrins* 1.000 0.500 Pass/<LOD
Pyridaben 0.200 0.100 Pass/<LOD Spinosad***** 0.200 0.100 Pass/<LOD
Spiromesifen 0.200 0.100 Pass/<LOD Spirotetramat 0.200 0.100 Pass/<LOD
Spiroxamine‡ 0.400 0.200 Pass/<LOD Tebuconazole 0.400 0.200 Pass/<LOD
Thiacloprid 0.200 0.100 Pass/<LOD Thiamethoxam 0.200 0.100 Pass/<LOD
Trifloxystrobin 0.200 0.100 Pass/<LOD

* Pyrethrins are reported as the sum of Jasmolin I, Cinerin I, and Pyrethrin I
** Cyfluthrins are reported as the sum of isomers Cyfluthrin I, II, III, and IV
*** Cypermethrins are reported as the sum of isomers Cypermethrin I, II, III, and IV
**** Abamectin is reported as the sum of Avermectin B1a and Avermectin B1b
***** Spinosad is reported as the sum of Spinosyn A and Spinosyn D
† Permethrin and Prallethrin are reported as the sum of cis and trans isomers
‡ MGK-264 and Spiroximine are reported as the sum of isomers I and II
MRL - Maximum Residue Limit; LOD - Limit of Detection

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Pesticide QC Report

Testing Accreditation #: 77802 Test Certificate #: 154046-001
Client Name, Sample Details

Greenroom Gardens LLC AU-G-C-000910
Muskegon, MI 49441
Sample: Banana Runtz
License: AU-G-C-000910
Type: Adult Use Flower
Method: FE-52 (EN 15662 & AOAC 2007.01)
Metrc Test Pkg#: 1A4050300032E11000001231
Metrc Source Pkg#: 1A4050300032E11000001230

Test Conditions

Prepsheet ID#: MIPS250314b
Scale: XS205-MI1
Temp: 23.8 °C
Baro PE: 978.1 hPa
Analyst: OSB
Technician: OSB

Sample ID#: 154046

Harvest/Process Date: 03/17/2025
Serving Size (g): 1
Date Received: 03/17/2025
Test Date: 03/14/2025
Valid Through: 03/14/2026
Report Issued: 03/17/2025

Sample #154046
Target Compound Name Method Blank (μg/g) QC Spike (μg/g) Matrix Spike (μg/g) Matrix Spike Duplicate (μg/g) MS recovery% MSD recovery% Relative Percent Difference (%) QC Flag
Acephate N.D. 1 1.18 1.13 118.00 113.00 4.33
Acequinocyl N.D. 1 1.35 1.31 135.00 131.00 3.01 HR
Acetamiprid N.D. 1 0.825 0.846 82.50 84.60 2.51
Aldicarb N.D. 1 1.06 1.01 106.00 101.00 4.83
Avermectin B1a N.D. 1 0.893 0.876 89.30 87.60 1.92
Azoxystrobin N.D. 1 0.763 0.694 76.30 69.40 9.47
Bifenazate N.D. 1 1.16 1.14 116.00 114.00 1.74
Bifenthrin N.D. 1 0.704 0.605 70.40 60.50 15.13
Boscalid N.D. 1 1.5 1.47 150.00 147.00 2.02 HR
Carbaryl N.D. 1 1.23 1.15 123.00 115.00 6.72 HR
Carbofuran N.D. 1 0.732 0.72 73.20 72.00 1.65
Chlorantraniliprole N.D. 1 0.698 0.667 69.80 66.70 4.54
Chlorfenapyr N.D. 1 3.19 2.83 319.00 283.00 11.96 HR
Chlorpyriphos N.D. 1 1.4 1.34 140.00 134.00 4.38 HR
Clofentezine N.D. 1 1 0.902 100.00 90.20 10.30
Cyfluthrin N.D. 1 0.807 0.729 80.70 72.90 10.16
Cypermethrin N.D. 1 0.87 0.801 87.00 80.10 8.26
Daminoside N.D. 1 < 0 < 0 0.00 0.00 LR
Diazanon N.D. 1 3.85 3.56 385.00 356.00 7.83 HR
Dichlorvos N.D. 1 0.627 0.607 62.70 60.70 3.24
Dimethoate N.D. 1 0.844 0.821 84.40 82.10 2.76
Ethoprophos N.D. 1 0.842 0.788 84.20 78.80 6.63
Etofenprox N.D. 1 1.13 1.01 113.00 101.00 11.21
Etoxazole N.D. 1 1.29 1.2 129.00 120.00 7.23 HR
Fenoxycarb N.D. 1 0.909 0.845 90.90 84.50 7.30
Fenpyroximate N.D. 1 0.921 0.842 92.10 84.20 8.96
Fipronil N.D. 1 1.49 1.54 149.00 154.00 3.30 HR
Flonicamid N.D. 1 0.788 0.743 78.80 74.30 5.88
Fludioxonil N.D. 1 1.2 1.18 120.00 118.00 1.68
Hexythiazox N.D. 1 1.37 1.24 137.00 124.00 9.96 HR
Imazalil N.D. 1 0.785 0.728 78.50 72.80 7.53
Imidacloprid N.D. 1 0.557 0.53 55.70 53.00 4.97 LR
Kresoxim-methyl N.D. 1 1.44 1.28 144.00 128.00 11.76 HR
Malathion N.D. 1 1.3 1.22 130.00 122.00 6.35 HR
Metalaxyl N.D. 1 0.766 0.729 76.60 72.90 4.95
Methiocarb N.D. 1 0.934 0.881 93.40 88.10 5.84
Methomyl N.D. 1 0.8 0.764 80.00 76.40 4.60
MGK-264 N.D. 1 0.929 0.92 92.90 92.00 0.97
Myclobutanil N.D. 1 0.728 0.738 72.80 73.80 1.36
Naled (dibrom) N.D. 1 0.404 0.351 40.40 35.10 14.04 LR
Oxamyl N.D. 1 0.717 0.715 71.70 71.50 0.28
Paclobutrazol N.D. 1 0.851 0.849 85.10 84.90 0.24
Parathion-methyl N.D. 1 1.71 1.6 171.00 160.00 6.65 HR
Permethrins N.D. 1 0.871 0.796 87.10 79.60 9.00
Phosmet N.D. 1 1.16 1.09 116.00 109.00 6.22
Piperonyl butoxide N/A N/A N/A N/A nan nan N/A
Prallethrin N.D. 1 1.04 0.982 104.00 98.20 5.74
Propiconazole N.D. 1 1.39 1.32 139.00 132.00 5.17 HR
Propoxur N.D. 1 0.945 0.912 94.50 91.20 3.55
Pyrethrin N.D. 1 1.53 1.44 153.00 144.00 6.06 HR
Pyridaben N.D. 1 1.27 1.19 127.00 119.00 6.50 HR
SpinosynA N.D. 0.82 0.567 0.523 69.15 63.78 8.07
SpinosynD N.D. 0.18 0.186 0.167 103.33 92.78 10.76
Spiromesifen N.D. 1 0.583 0.542 58.30 54.20 7.29 LR
Spirotetramat N.D. 1 1.58 1.43 158.00 143.00 9.97 HR
Spiroxamine N.D. 1 0.86 0.756 86.00 75.60 12.87
Tebuconazole N.D. 1 1.08 1.01 108.00 101.00 6.70
Thiacloprid N.D. 1 0.742 0.703 74.20 70.30 5.40
Thiamethoxam N.D. 1 0.741 0.747 74.10 74.70 0.81
Trifloxystrobin N.D. 1 1.02 0.914 102.00 91.40 10.96

N.D. = Not Detected

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 30%

R = indicates compound recovery of matrix spike was outside the methods acceptable limits. (60-120%) Low recovery could indicate there is actually more compound present than detected; while high recoveries should be scrutinized for possible fails as more compound may be detected than is actually residual on the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ARH - LM Iron laboratories ARH - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 3 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Microbiology Analysis

Testing Accreditation #: 77802 Test Certificate #: 154046-001
Client Name, Sample Details

Greenroom Gardens LLC AU-G-C-000910
Muskegon, MI 49441
Sample: Banana Runtz
License: AU-G-C-000910
Type: Adult Use Flower
Metrc Test Pkg#: 1A4050300032E11000001231
Metrc Source Pkg#: 1A4050300032E11000001230

Test Conditions

Scale: Pioneer-MI1
Temp: 22.6 °C
Baro Pressure: 975.6 hPa
Analyst: EDB
Technician: EDB

Sample ID#: 154046

Harvest/Process Date: 03/17/2025
Serving Size (g): 1
Date Received: 03/17/2025
Test Date: 03/17/2025
Valid Through: 03/17/2026
Report Issued: 03/20/2025

Sample #154046
Test Method MCFU (CFU/g) LOD (CFU/g) Status (CFU/g)
Total Aerobic Not Tested N/A 0 Not Tested
Yeast & Mold FE-66 (MPN) 100,001 100 Pass/<LOD
Bile-tolerant gram-negative bacteria Not Tested N/A 0 Not Tested
Total Coliforms FE-66 (MPN) 1,001 100 Pass/<LOD
E. Coli FE-65 (PCR) 1 1 Pass/Not Present
Salmonella FE-65 (PCR) 1 1 Pass/Not Present
Aspergillus spp. FE-65 (PCR) 1 1 Pass/Not Present

E. coli test screens exclusively for Shiga toxin-producing E. coli. TNTC values for yeast and mold are >150,000 CFU/g. TNTC values for total coliforms are >15,000 CFU/g. The maximum relative uncertainty is 6% for PCR and 40% for MPN.

TNTC = Too Numerous To Count. Maximum Colony Forming Units (MCFU) represents the minimum value that a test would need to achieve in order to be considered a failed result (if applicable). LOD is the Limit of Detection for the method. CFU/g = Colony Forming Units per gram. Aspergillus spp. consists of A. flavus, A. fumigatus, A. niger, and A. terreus.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 4 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Bio Analysis by
Microscopic Visual Inspection

Testing Accreditation #: 77802 Test Certificate #: 154046-001
Client Name, Sample Details

Greenroom Gardens LLC AU-G-C-000910
Muskegon, MI 49441
Sample: Banana Runtz
License: AU-G-C-000910
Type: Adult Use Flower
Method: FE02 Microscope Dissection
Metrc Test Pkg#: 1A4050300032E11000001231
Metrc Source Pkg#: 1A4050300032E11000001230

Test Conditions

Analyst: ARH
Technician: ARH

Sample ID#: 154046

Harvest/Process Date: 03/17/2025
Serving Size (g): 1
Date Received: 03/17/2025
Test Date: 03/17/2025
Valid Through: 03/17/2026
Report Issued: 03/17/2025

Sample #154046
Sample #154046 Sample #154046
Severity Rating
Mold and Mildew 0 Pass
Mites (not Russet) 0 Pass
Russet Mites 0 Pass
Thrips 0 Pass
Aphids 0 Pass
Other Pests 0 Pass
Other Organic Matter 0 Pass
Inorganic Matter 0 Pass
Total Organic Foreign Matter <2% Pass
Inorganic Foreign Matter 0% Pass
Stem Material <5% Pass
Severity Rating Key
Correlating %FM ≤2% FM >2% FM
Severity Rating 0 None 1 Mild 2 Moderate 3 Severe Units
Mold and Mildew <2 2 3 4+ Locations/g
Mites (not russet) <1 1-5 6-10 11+ Amount/g
Russet Mites <1 1-10 11-50 51+ Amount/g
Thrips <1 1-3 4-5 6+ Amount/g
Aphids <1 1 2-4 5+ Amount/g
Other Pests <1 1-5 6-10 11+ Amount/g
Other Organic Matter <1 1-5 6-10 11+ Amount/g
Inorganic Matter 0 >0 Amount/g

In compliance with the MMFLA regulation, the action limits for foreign matter are as follows; no more that 2% organic matter, 5% stem material, and no presence of inorganic matter. Percent foreign contamination is based off of total surface area.

Scale: PIONEER-MI1.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 5 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Heavy Metals Analysis

Testing Accreditation #: 77802 Test Certificate #: 154046-001
Client Name, Sample Details

Greenroom Gardens LLC AU-G-C-000910
Muskegon, MI 49441
Sample: Banana Runtz
License: AU-G-C-000910
Type: Adult Use Flower
Method: FE60 ICPMS-MI
Metrc Test Pkg#: 1A4050300032E11000001231
Metrc Source Pkg#: 1A4050300032E11000001230

Test Conditions

Prepsheet ID#: HMMIICP250214fMK
Temp: 23.0 °C
Baro PE: 979.3 hPa
Analyst: MK
Technician: MK

Sample ID#: 154046

Harvest/Process Date: 03/17/2025
Serving Size (g): 1
Date Received: 03/17/2025
Test Date: 03/14/2025
Valid Through: 03/14/2026
Report Issued: 03/20/2025

Sample #154046
Sample #154046 Sample #154046
Test Compound MRL (PPM) LOD (PPM) Status (PPM)
Arsenic 0.4 0.1 Pass/0.399
Copper 0 1.5 Not Tested
Cadmium 0.4 0.1 Pass/<LOD
Chromium 1.2 0.3 Pass/<LOD
Lead 1 0.25 Pass/<LOD
Mercury 0.2 0.05 Pass/<LOD
Nickel 1 0.25 Pass/<LOD

MRL - Maximum Residue Limit; LOD - Limit of Detection

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 6 of 6

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 154046-001
Client Name, Sample Details

Greenroom Gardens LLC AU-G-C-000910
Muskegon, MI 49441
Sample: Banana Runtz
License: AU-G-C-000910
Type: Adult Use Flower
Method: FE60 ICPMS-MI
Metrc Test Pkg#: 1A4050300032E11000001231
Metrc Source Pkg#: 1A4050300032E11000001230

Test Conditions

Prepsheet ID#: HMMIICP250214fMK
Temp: 23.0 °C
Baro PE: 979.3 hPa
Analyst: MK
Technician: MK

Sample ID#: 154046

Harvest/Process Date: 03/17/2025
Serving Size (g): 1
Date Received: 03/17/2025
Test Date: 03/14/2025
Valid Through: 03/14/2026
Report Issued: 03/20/2025

Sample #154046
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD QC Flag
Arsenic N/D 0.160 0.153 95.63 0.156 97.50
Cadmium N/D 0.160 0.157 98.13 0.154 96.25
Chromium N/D 0.480 0.357 74.38 0.370 77.08
Copper N/D 2.400 2.313 96.38 2.347 97.79
Lead N/D 0.400 0.394 98.50 0.387 96.75
Mercury N/D 0.080 0.086 107.50 0.084 105.00
Nickel N/D 0.400 0.386 96.50 0.388 97.00

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 7 of 6