IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 77802 Test Certificate #: 140130-001
Client Name, Sample Details

Northern Connections / Truu Cannabis (AU-P-000247)
Lansing , MI 48910
Sample: Black Cherry Liquid Loud 200mg
License: AU-P-000247
Type: Infused Product
Method: FE04U12 HPLC-UV
Metrc Test Pkg#: 1A4050300029041000003501
Metrc Source Pkg#: 1A4050300029041000003498
***Water Activity: 0.84

Test Conditions

Prepsheet ID#: MIP230419B
Scale: XS205-MI2
Temp: 21.5 °C
Baro Pressure: 980.7 hPa
Analyst: KEB
Technician: KEB

Sample ID#: 140130

Harvest/Process Date: 03/28/2023
Serving Size (g): 3.55
Date Received: 03/28/2023
Test Date: 03/29/2023
Valid Through: 03/29/2024
Report Issued: 03/30/2023

Sample #140130
Sample #140130 Sample #140130
Test
Compounds
Δ9-THC THCA Δ8-THC CBD CBDA CBG CBGA CBN CBC CBL THCV CBDV Total
Cannabinoids*
Total THC Total CBD Calc Max Total
Cannabinoids*
Amount (%) 0.3 N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D N/D 0.3 0.3 0.0 0.3
Amount (mg/g) 2.9 N/D N/D N/D N/D N/D N/D N/D 0.1 N/D N/D N/D 3 2.9 0.0 3.0
Amount per Serving (mg) 10.295 N/D N/D N/D N/D N/D N/D N/D 0.355 N/D N/D N/D 10.7 Serving Size~ (g): 3.6
LOQ (mg/g) 0.04 0.04 0.04 0.04 0.04 0.04 0.04 0.04 0.04 0.04 0.04 0.04   %Decarb. THC CBD
±%RPD 1.63% 4.64% 0.85% 0.09% 0.91% 1.25% 1.34% 0.93% 1.27% 0.69% 0.76% 0.96% 100% N/A

Serving size = 3.86mL = 3.55g. 20 servings per container. . Sample passes for water activity (sample fails if Aw>0.85).

LOQ = Limit of Quantitation; %RPD = Relative Percent Deviation; %RSD = Relative Standard Deviation; N/D = Not Detected

*Designates values that are not currently included in the accredited scope of Iron Laboratories.

*** Designates tests that use the method FE-45. FE-45 is performed using AOAC 966.02 and 32.004-32.009.

FE-45 has relative expanded (k=2) uncertainties of 1.098% for moisture, 1.754% for water activity for unprocessed plant materials, and 13.102% for water activity for infused products.

Vitamin E acetate analysis has a relative expanded (k=2) uncertainty of 18.614%.

Total THC and CBD is the calculated sum of Δ9-THC and Δ8-THC or CBD plus the amount of THC or CBD derived from THCA or CBDA, respectively.

These values are calculated by applying a molar correction factor of 0.877 to the THCA or the CBDA value.

Calc Max Total Cannabinoids is the sum of Total THC, Total CBD, CBN, Total CBG, CBC, THCV, CBDV, and CBL.

Total CBG is calculated as CBG plus CBGA*0.878 (the molar correction factor for CBGA to CBG conversion).

%Decarb. THC and CBD refer to the percentage of Δ9-THC or CBD relative to THCA or CBDA, respectively.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

KEB - LM Iron laboratories KEB - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 8

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 140130-001
Client Name, Sample Details

Northern Connections / Truu Cannabis (AU-P-000247)
Lansing , MI 48910
Sample: Black Cherry Liquid Loud 200mg
License: AU-P-000247
Type: Infused Product
Method: FE04U12 HPLC-UV
Metrc Test Pkg#: 1A4050300029041000003501
Metrc Source Pkg#: 1A4050300029041000003498
***Water Activity: 0.84

Test Conditions

Prepsheet ID#: MIP230419B
Scale: XS205-MI2
Temp: 21.5 °C
Baro Pressure: 980.7 hPa
Analyst: KEB
Technician: KEB

Sample ID#: 140130

Harvest/Process Date: 03/28/2023
Serving Size (g): 3.55
Date Received: 03/28/2023
Test Date: 03/29/2023
Valid Through: 03/29/2024
Report Issued: 03/30/2023

Sample #140130
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD Relative Percent Difference (%) QC Flag
Δ9-THC 0 5.09561 5.21184 102.28 5.12783 100.63 1.63%
THCA 0 5.03324 4.89048 97.16 5.12301 101.78 4.64%
Δ8-THC 0 4.89936 5.07542 103.59 5.03257 102.72 0.85%
CBD 0 5.20184 5.23806 100.70 5.24302 100.79 0.09%
CBDA 0 5.16573 5.06419 98.03 5.11039 98.93 0.91%
CBG 0 5.15125 5.16248 100.22 5.0985 98.98 1.25%
CBGA 0 5.10319 4.99823 97.94 5.06558 99.26 1.34%
CBN 0 5.11643 5.06293 98.95 5.10998 99.87 0.93%
CBC 0 5.04055 4.96931 98.59 5.03292 99.85 1.27%
CBCA N/A 0 0 0.00 0 0.00 0%
CBL 0 5.08273 5.01794 98.73 5.05251 99.41 0.69%
THCV 0 4.9046 4.98909 101.72 5.02703 102.50 0.76%
CBDV 0 5.13945 5.06067 98.47 5.10949 99.42 0.96%

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

KEB - LM Iron laboratories KEB - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 8

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Pesticide Analysis by
Mass Spectrometer

Testing Accreditation #: 77802 Test Certificate #: 140130-001
Client Name, Sample Details

Northern Connections / Truu Cannabis (AU-P-000247)
Lansing , MI 48910
Sample: Black Cherry Liquid Loud 200mg
License: AU-P-000247
Type: Infused Product
Method: FE-52 (EN 15662 & AOAC 2007.01)
Metrc Test Pkg#: 1A4050300029041000003501
Metrc Source Pkg#: 1A4050300029041000003498

Test Conditions

Prepsheet ID#: MIPS230330a
Scale: 19
Temp: 22.4 °C
Baro PE: 989.1 hPa
Analyst: MEH
Technician: MK

Sample ID#: 140130

Harvest/Process Date: 03/28/2023
Serving Size (g): 3.55
Date Received: 03/28/2023
Test Date: 03/30/2023
Valid Through: 03/29/2024
Report Issued: 03/31/2023

Sample #140130
Compound MRL (µg/g) LOD (µg/g) Status (µg/g)   Compound MRL (µg/g) LOD (µg/g) Status (µg/g)
Aldicarb 0.400 0.125 Pass/<LOD Abamectin**** 0.500 0.125 Pass/<LOD
Acephate 0.400 0.125 Pass/<LOD Acequinocyl 2.000 0.250 Pass/<LOD
Acetamiprid 0.200 0.125 Pass/<LOD Azoxystrobin 0.200 0.125 Pass/<LOD
Bifenazate 0.200 0.125 Pass/<LOD Bifenthrin 0.200 0.125 Pass/<LOD
Boscalid 0.400 0.125 Pass/<LOD Carbaryl 0.200 0.125 Pass/<LOD
Carbofuran 0.200 0.125 Pass/<LOD Chlorantraniliprole 0.200 0.125 Pass/<LOD
Chlorfenapyr 1.000 0.500 Pass/<LOD Chlorpyrifos 0.200 0.125 Pass/<LOD
Clofentezine 0.200 0.125 Pass/<LOD Cyfluthrin** 1.000 0.500 Pass/<LOD
Cypermethrin*** 1.000 0.500 Pass/<LOD Daminozide 1.000 0.500 Pass/<LOD
DDVP (Dichlorvos) 1.000 0.250 Pass/<LOD Diazinon 0.200 0.125 Pass/<LOD
Dimethoate 0.200 0.125 Pass/<LOD Ethoprophos 0.200 0.125 Pass/<LOD
Etofenprox 0.400 0.125 Pass/<LOD Etoxazole 0.200 0.125 Pass/<LOD
Fenoxycarb 0.200 0.125 Pass/<LOD Fenpyroximate 0.400 0.125 Pass/<LOD
Fipronil 0.400 0.125 Pass/<LOD Flonicamid 1.000 0.125 Pass/<LOD
Fludioxonil 0.400 0.125 Pass/<LOD Hexythiazox 1.000 0.125 Pass/<LOD
Imazalil 0.200 0.125 Pass/<LOD Imidacloprid 0.400 0.125 Pass/<LOD
Kresoxim Methyl 0.400 0.125 Pass/<LOD Malathion 0.200 0.125 Pass/<LOD
Metalaxyl 0.200 0.125 Pass/<LOD Methiocarb 0.200 0.125 Pass/<LOD
Methomyl 0.400 0.125 Pass/<LOD Methyl Parathion 0.200 0.125 Pass/<LOD
MGK-264‡ 0.200 0.125 Pass/<LOD Myclobutanil 0.200 0.125 Pass/<LOD
Naled 0.500 0.125 Pass/<LOD Oxamyl 1.000 0.125 Pass/<LOD
Paclobutrazol 0.400 0.125 Pass/<LOD Permethrins† 0.200 0.125 Pass/<LOD
Phosmet 0.200 0.125 Pass/<LOD Piperonyl Butoxide 100.000 1.900 Not Tested
Prallethrin 0.200 0.125 Pass/<LOD Propiconazole 0.400 0.125 Pass/<LOD
Propoxur 0.200 0.125 Pass/<LOD Pyrethrins* 1.000 0.125 Pass/<LOD
Pyridaben 0.200 0.125 Pass/<LOD Spinosad***** 0.200 0.125 Pass/<LOD
Spiromesifen 0.200 0.125 Pass/<LOD Spirotetramat 0.200 0.125 Pass/<LOD
Spiroxamine‡ 0.400 0.125 Pass/<LOD Tebuconazole 0.400 0.125 Pass/<LOD
Thiacloprid 0.200 0.125 Pass/<LOD Thiamethoxam 0.200 0.125 Pass/<LOD
Trifloxystrobin 0.200 0.125 Pass/<LOD

* Pyrethrins are reported as the sum of Jasmolin I, Cinerin I, and Pyrethrin I
** Cyfluthrins are reported as the sum of isomers Cyfluthrin I, II, III, and IV
*** Cypermethrins are reported as the sum of isomers Cypermethrin I, II, III, and IV
**** Abamectin is reported as the sum of Avermectin B1a and Avermectin B1b
***** Spinosad is reported as the sum of Spinosyn A and Spinosyn D
† Permethrin and Prallethrin are reported as the sum of cis and trans isomers
‡ MGK-264 and Spiroximine are reported as the sum of isomers I and II
MRL - Maximum Residue Limit; LOD - Limit of Detection

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

KEB - LM Iron laboratories KEB - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 8

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Pesticide QC Report

Testing Accreditation #: 77802 Test Certificate #: 140130-001
Client Name, Sample Details

Northern Connections / Truu Cannabis (AU-P-000247)
Lansing , MI 48910
Sample: Black Cherry Liquid Loud 200mg
License: AU-P-000247
Type: Infused Product
Method: FE-52 (EN 15662 & AOAC 2007.01)
Metrc Test Pkg#: 1A4050300029041000003501
Metrc Source Pkg#: 1A4050300029041000003498

Test Conditions

Prepsheet ID#: MIPS230330a
Scale: 19
Temp: 22.4 °C
Baro PE: 989.1 hPa
Analyst: MEH
Technician: MK

Sample ID#: 140130

Harvest/Process Date: 03/28/2023
Serving Size (g): 3.55
Date Received: 03/28/2023
Test Date: 03/30/2023
Valid Through: 03/29/2024
Report Issued: 03/31/2023

Sample #140130
Target Compound Name Method Blank (μg/g) QC Spike (μg/g) Matrix Spike (μg/g) Matrix Spike Duplicate (μg/g) MS recovery% MSD recovery% Relative Percent Difference (%) QC Flag
Acephate N.D. 1 1.26 1.08 126.00 108.00 15.38 HR
Acequinocyl N.D. 1 0.808 0.679 80.80 67.90 17.35
Acetamiprid N.D. 1 1.16 1.08 116.00 108.00 7.14
Aldicarb N.D. 1 1.07 1.19 107.00 119.00 10.62
Avermectin B1a N.D. 1 0.743 0.628 74.30 62.80 16.78
Azoxystrobin N.D. 1 0.935 0.947 93.50 94.70 1.28
Bifenazate N.D. 1 0.798 0.682 79.80 68.20 15.68
Bifenthrin N.D. 1 0.927 0.941 92.70 94.10 1.50
Boscalid N.D. 1 0.992 0.945 99.20 94.50 4.85
Carbaryl N.D. 1 1.09 1.04 109.00 104.00 4.69
Carbofuran N.D. 1 0.926 1.07 92.60 107.00 14.43
Chlorantraniliprole N.D. 1 0.921 0.815 92.10 81.50 12.21
Chlorfenapyr N.D. 1 0.94 0.781 94.00 78.10 18.48
Chlorpyriphos N.D. 1 1.03 1.03 103.00 103.00 0.00
Clofentezine N.D. 1 0.848 0.968 84.80 96.80 13.22
Cyfluthrin N.D. 1 1 0.911 100.00 91.10 9.31
Cypermethrin N.D. 1 0.852 0.898 85.20 89.80 5.26
Daminoside N.D. 1 0.282 0.246 28.20 24.60 13.64 LR
Diazanon N.D. 1 1.31 1.18 131.00 118.00 10.44 HR
Dichlorvos N.D. 1 0.996 1.12 99.60 112.00 11.72
Dimethoate N.D. 1 1.05 1.19 105.00 119.00 12.50
Ethoprophos N.D. 1 0.946 0.848 94.60 84.80 10.93
Etofenprox N.D. 1 0.919 0.976 91.90 97.60 6.02
Etoxazole N.D. 1 1.01 1.01 101.00 101.00 0.00
Fenoxycarb N.D. 1 0.878 0.984 87.80 98.40 11.39
Fenpyroximate N.D. 1 0.933 0.847 93.30 84.70 9.66
Fipronil N.D. 1 1.18 1.19 118.00 119.00 0.84
Flonicamid N.D. 1 1.36 0.675 136.00 67.50 67.32 HRQ
Fludioxonil N.D. 1 1.26 1.36 126.00 136.00 7.63 HR
Hexythiazox N.D. 1 1.02 0.935 102.00 93.50 8.70
Imazalil N.D. 1 0.911 0.832 91.10 83.20 9.06
Imidacloprid N.D. 1 1.07 0.975 107.00 97.50 9.29
Kresoxim-methyl N.D. 1 1.14 1.06 114.00 106.00 7.27
Malathion N.D. 1 1.01 0.888 101.00 88.80 12.86
Metalaxyl N.D. 1 1.02 1.04 102.00 104.00 1.94
Methiocarb N.D. 1 1.15 1.1 115.00 110.00 4.44
Methomyl N.D. 1 0.943 0.849 94.30 84.90 10.49
MGK-264 N.D. 1 1.011 0.867 101.10 86.70 15.34
Myclobutanil N.D. 1 0.931 0.976 93.10 97.60 4.72
Naled (dibrom) N.D. 1 0.605 0.53 60.50 53.00 13.22 LR
Oxamyl N.D. 1 0.946 0.871 94.60 87.10 8.26
Paclobutrazol N.D. 1 0.982 1.07 98.20 107.00 8.58
Parathion-methyl N.D. 1 1.03 1.13 103.00 113.00 9.26
Permethrins N.D. 1 0.879 0.762 87.90 76.20 14.26
Phosmet N.D. 1 0.89 0.907 89.00 90.70 1.89
Piperonyl butoxide N/A N/A N/A N/A nan nan N/A
Prallethrin N.D. 1 0.927 0.863 92.70 86.30 7.15
Propiconazole N.D. 1 0.9 0.889 90.00 88.90 1.23
Propoxur N.D. 1 1.01 0.937 101.00 93.70 7.50
Pyrethrin N.D. 1 0.931 0.951 93.10 95.10 2.13
Pyridaben N.D. 1 0.953 0.928 95.30 92.80 2.66
SpinosynA N.D. 0.82 0.544 0.533 66.34 65.00 2.04
SpinosynD N.D. 0.18 0.168 0.156 93.33 86.67 7.41
Spiromesifen N.D. 1 0.596 0.589 59.60 58.90 1.18 LR
Spirotetramat N.D. 1 0.892 0.797 89.20 79.70 11.25
Spiroxamine N.D. 1 0.935 0.929 93.50 92.90 0.64
Tebuconazole N.D. 1 0.996 0.953 99.60 95.30 4.41
Thiacloprid N.D. 1 1.12 0.971 112.00 97.10 14.25
Thiamethoxam N.D. 1 1.37 0.995 137.00 99.50 31.71 HRQ
Trifloxystrobin N.D. 1 0.928 0.928 92.80 92.80 0.00

N.D. = Not Detected

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 30%

R = indicates compound recovery of matrix spike was outside the methods acceptable limits. (60-120%) Low recovery could indicate there is actually more compound present than detected; while high recoveries should be scrutinized for possible fails as more compound may be detected than is actually residual on the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

KEB - LM Iron laboratories KEB - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 3 of 8

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Residual Solvents Analysis by
Mass Spectrometer

Testing Accreditation #: 77802 Test Certificate #: 140130-001
Client Name, Sample Details

Northern Connections / Truu Cannabis (AU-P-000247)
Lansing , MI 48910
Sample: Black Cherry Liquid Loud 200mg
License: AU-P-000247
Type: Infused Product
Method: SOP FE-44-MI
Metrc Test Pkg#: 1A4050300029041000003501
Metrc Source Pkg#: 1A4050300029041000003498

Test Conditions

Prepsheet ID#: MIHS230329a
Scale: XS205-MI1
Temp: 21.8 °C
Baro PE: 974.5 hPa
Analyst: MEH
Technician: MEH

Sample ID#: 140130

Harvest/Process Date: 03/28/2023
Serving Size (g): 3.55
Date Received: 03/28/2023
Test Date: 03/29/2023
Valid Through: 03/28/2024
Report Issued: 03/31/2023

Sample #140130
Compound MRL (µg/g) LOD (µg/g) Status (µg/g)   Compound MRL (µg/g) LOD (µg/g) Status (µg/g)
1,2-Dichloroethane 5 1 Pass/<LOD 1,2-Dimethoxyethane 5,000 250 Not Tested
1,4-dioxane 5,000 25 Not Tested 1-Butanol 5,000 250 Not Tested
1-Pentanol 5,000 250 Not Tested 1-Propanol 5,000 250 Not Tested
2,2-Dimethylpropane (Neopentane) 5,000 25 Pass/<LOD 2,2-Dimethylbutane (Hexanes) 290 25 Pass/<LOD
2,3-Dimethylbutane (Hexanes) 290 25 Pass/<LOD 2-Butanol 5,000 25 Not Tested
2-Butanone (MEK) 5,000 250 Not Tested 2-Ethoxyethanol 5,000 25 Not Tested
2-Methylbutane (Isopentane) 5,000 25 Pass/<LOD 2-Methylpentane (Hexanes) 290 25 Pass/<LOD
2-Methylpropane (Isobutane) 5,000 25 Pass/<LOD 2-propanol (Isopropyl Alcohol) 5,000 25 Pass/<LOD
2-Propanone (Acetone) 5,000 25 Pass/<LOD 3-Methylpentane (Hexanes) 290 25 Pass/<LOD
Acetonitrile 410 30 Pass/<LOD Benzene 2 1 Pass/<LOD
Butane 5,000 25 Pass/<LOD Chloroform 60 1 Pass/<LOD
Cumene 5,000 25 Not Tested Cyclohexane 290 25 Not Tested
Dichloromethane 600 25 Pass/<LOD Dimethylsulfoxide (DMSO) 5,000 250 Not Tested
Ethanol 5,000 50 Pass/<LOD Ethyl acetate 5,000 25 Pass/<LOD
Ethyl ether 5,000 25 Pass/<LOD Ethylene glycol 5,000 25 Not Tested
Ethylene oxide 50 3 Pass/<LOD Heptane 5,000 25 Pass/<LOD
Hexane 290 25 Pass/<LOD Isopropyl acetate 5,000 25 Not Tested
Methanol 3,000 125 Pass/<LOD Naptha 400 100 Not Tested
N,N-Dimethylacetamide 5,000 250 Not Tested N,N-Dimethylformamide (DMF) 5,000 250 Not Tested
Pentane 5,000 25 Pass/<LOD Petroleum Ether 400 100 Not Tested
Propane 5,000 25 Pass/<LOD Pyridine 5,000 250 Not Tested
Sulfolane 5,000 25 Not Tested Tetrahydrofuran (THF) 5,000 25 Not Tested
Toluene 890 25 Pass/<LOD Trichloroethylene 80 25 Pass/<LOD
Xylenes* 2,170 25 Pass/<LOD

Total Butanes = 0 ug/g (PASS); Total Pentanes = 0 ug/g (PASS); Total Hexanes = 0 ug/g (PASS)

* Xylenes are reported as the sum of o-xylene, m-xylene, p-xylene, and ethylbenzene
MRL - Maximum Residue Limit; LOD - Limit of Detection

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

KEB - LM Iron laboratories KEB - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 4 of 8

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Residual Solvents QC Report

Testing Accreditation #: 77802 Test Certificate #: 140130-001
Client Name, Sample Details

Northern Connections / Truu Cannabis (AU-P-000247)
Lansing , MI 48910
Sample: Black Cherry Liquid Loud 200mg
License: AU-P-000247
Type: Infused Product
Method: SOP FE-44-MI
Metrc Test Pkg#: 1A4050300029041000003501
Metrc Source Pkg#: 1A4050300029041000003498

Test Conditions

Prepsheet ID#: MIHS230329a
Scale: XS205-MI1
Temp: 21.8 °C
Baro PE: 974.5 hPa
Analyst: MEH
Technician: MEH

Sample ID#: 140130

Harvest/Process Date: 03/28/2023
Serving Size (g): 3.55
Date Received: 03/28/2023
Test Date: 03/29/2023
Valid Through: 03/28/2024
Report Issued: 03/31/2023

Sample #140130
Target Compound Name Method Blank (μg/g) QC Spike (μg/g) Matrix Spike (μg/g) Matrix Spike Duplicate (μg/g) MS Recovery (%) MSD Recovery (%) Relative Percent Difference (%) QC Flag
1,2-Dichloroethane N.D. 250 245 251 98.00 100.40 2.42
n-Propane N.D. 250 259 264 103.60 105.60 1.91
Isobutane N.D. 250 255 269 102.00 107.60 5.34
Methanol N.D. 250 252 252 100.80 100.80 0.00
n-Butane N.D. 250 245 255 98.00 102.00 4.00
2,2-Dimethylpropane N.D. 250 252 262 100.80 104.80 3.89
Ethanol N.D. 250 241 248 96.40 99.20 2.86
Isopentane N.D. 250 247 260 98.80 104.00 5.13
Acetonitrile N.D. 250 244 245 97.60 98.00 0.41
Diethyl ether N.D. 250 240 246 96.00 98.40 2.47
2-propanone N.D. 250 242 254 96.80 101.60 4.84
2-propanol 50.81 250 237 238 94.80 95.20 0.42 I
n-Pentane N.D. 250 259 282 103.60 112.80 8.50
2,2-Dimethylbutane N.D. 250 244 266 97.60 106.40 8.63
2,3-Dimethylbutane N.D. 250 248 253 99.20 101.20 2.00
Methylene chloride N.D. 250 240 247 96.00 98.80 2.87
2-Methylpentane N.D. 250 244 255 97.60 102.00 4.41
3-Methylpentane N.D. 250 242 249 96.80 99.60 2.85
2-Butanol N.D. 0 0 0 0.00 0.00 0.00
n-Hexane N.D. 250 237 241 94.80 96.40 1.67
Ethyl acetate N.D. 250 241 242 96.40 96.80 0.41
Tetrahydrofuran N.D. 0 0 0 0.00 0.00 0.00
Trichloroethylene N.D. 250 243 240 97.20 96.00 1.24
Isopropyl acetate N.D. 0 0 0 0.00 0.00 0.00
Benzene N.D. 250 236 241 94.40 96.40 2.10
Chloroform N.D. 250 249 251 99.60 100.40 0.80
Cyclohexane N.D. 0 0 0 0.00 0.00 0.00
Ethylene glycol N.D. 0 0 0 0.00 0.00 0.00
Heptane N.D. 250 240 235 96.00 94.00 2.11
2-Ethoxyethanol N.D. 0 0 0 0.00 0.00 0.00
1,4-Dioxane N.D. 0 0 0 0.00 0.00 0.00
Pyridine N.D. 0 0 0 0.00 0.00 0.00
Toluene N.D. 250 232 236 92.80 94.40 1.71
Chlorobenzene N.D. 0 0 0 0.00 0.00 0.00
Ethylbenzene N.D. 0 0 0 0.00 0.00 0.00
m-Xylene/p-Xylene N.D. 500 458 463 91.60 92.60 1.09
o-Xylene N.D. 250 228 229 91.20 91.60 0.44
Cumene N.D. 0 0 0 0.00 0.00 0.00
Ethylene oxide N.D. 250 251 253 100.40 101.20 0.79

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

R = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery could indicate there is actually more compound present than detected; while high recoveries should be scrutinized for possible fails as more compound may be detected than is actually residual on the sample.

N.D. = Not Detected

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

KEB - LM Iron laboratories KEB - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 5 of 8

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Microbiology Analysis

Testing Accreditation #: 77802 Test Certificate #: 140130-001
Client Name, Sample Details

Northern Connections / Truu Cannabis (AU-P-000247)
Lansing , MI 48910
Sample: Black Cherry Liquid Loud 200mg
License: AU-P-000247
Type: Infused Product
Metrc Test Pkg#: 1A4050300029041000003501
Metrc Source Pkg#: 1A4050300029041000003498

Test Conditions

Scale: XS205-MI1
Temp: 20.7 °C
Baro Pressure: 985.7 hPa
Analyst: SKM
Technician: SKM

Sample ID#: 140130

Harvest/Process Date: 03/28/2023
Serving Size (g): 3.55
Date Received: 03/28/2023
Test Date: 03/29/2023
Valid Through: 03/28/2024
Report Issued: 04/03/2023

Sample #140130
Test Method MCFU (CFU/g) LOD (CFU/g) Status (CFU/g)
Total Aerobic Not Tested N/A 0 Not Tested
Yeast & Mold FE-66 (MPN) 10,001 100 Pass/206
Bile-tolerant gram-negative bacteria Not Tested N/A 0 Not Tested
Total Coliforms FE-66 (MPN) 101 100 Pass/<LOD
E. Coli FE-65 (PCR) 1 1 Pass/Not Present
Salmonella FE-65 (PCR) 1 1 Pass/Not Present
Aspergillus spp. FE-65 (PCR) 1 1 Pass/Not Present

E. coli test screens exclusively for Shiga toxin-producing E. coli. TNTC values for yeast and mold are >150,000 CFU/g. TNTC values for total coliforms are >15,000 CFU/g. The maximum relative uncertainty is 6% for PCR and 40% for MPN.

TNTC = Too Numerous To Count. Maximum Colony Forming Units (MCFU) represents the minimum value that a test would need to achieve in order to be considered a failed result (if applicable). LOD is the Limit of Detection for the method. CFU/g = Colony Forming Units per gram. Aspergillus spp. consists of A. flavus, A. fumigatus, A. niger, and A. terreus.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 6 of 8

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Bio Analysis by
Microscopic Visual Inspection

Testing Accreditation #: 77802 Test Certificate #: 140130-001
Client Name, Sample Details

Northern Connections / Truu Cannabis (AU-P-000247)
Lansing , MI 48910
Sample: Black Cherry Liquid Loud 200mg
License: AU-P-000247
Type: Infused Product
Method: FE02 Microscope Dissection
Metrc Test Pkg#: 1A4050300029041000003501
Metrc Source Pkg#: 1A4050300029041000003498

Test Conditions

Analyst: ARH
Technician: ARH

Sample ID#: 140130

Harvest/Process Date: 03/28/2023
Serving Size (g): 3.55
Date Received: 03/28/2023
Test Date: 03/29/2023
Valid Through: 03/28/2024
Report Issued: 03/29/2023

Sample #140130
Sample #140130 Sample #140130
Severity Rating
Mold and Mildew 0 Pass
Mites (not Russet) 0 Pass
Russet Mites 0 Pass
Thrips 0 Pass
Aphids 0 Pass
Other Pests 0 Pass
Other Organic Matter 0 Pass
Inorganic Matter 0 Pass
Total Organic Foreign Matter <2% Pass
Inorganic Foreign Matter 0% Pass
Stem Material <5% Pass
Severity Rating Key
Correlating %FM ≤2% FM >2% FM
Severity Rating 0 None 1 Mild 2 Moderate 3 Severe Units
Mold and Mildew <2 2 3 4+ Locations/g
Mites (not russet) <1 1-5 6-10 11+ Amount/g
Russet Mites <1 1-10 11-50 51+ Amount/g
Thrips <1 1-3 4-5 6+ Amount/g
Aphids <1 1 2-4 5+ Amount/g
Other Pests <1 1-5 6-10 11+ Amount/g
Other Organic Matter <1 1-5 6-10 11+ Amount/g
Inorganic Matter 0 >0 Amount/g

In compliance with the MMFLA regulation, the action limits for foreign matter are as follows; no more that 2% organic matter, 5% stem material, and no presence of inorganic matter. Percent foreign contamination is based off of total surface area.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 7 of 8

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Heavy Metals Analysis

Testing Accreditation #: 77802 Test Certificate #: 140130-001
Client Name, Sample Details

Northern Connections / Truu Cannabis (AU-P-000247)
Lansing , MI 48910
Sample: Black Cherry Liquid Loud 200mg
License: AU-P-000247
Type: Infused Product
Method: FE60 ICPMS-MI
Metrc Test Pkg#: 1A4050300029041000003501
Metrc Source Pkg#: 1A4050300029041000003498

Test Conditions

Prepsheet ID#: MIICP 230329gMK
Temp: 22.4 °C
Baro PE: 989.2 hPa
Analyst: MK
Technician: MK

Sample ID#: 140130

Harvest/Process Date: 03/28/2023
Serving Size (g): 3.55
Date Received: 03/28/2023
Test Date: 03/29/2023
Valid Through: 03/28/2024
Report Issued: 03/30/2023

Sample #140130
Sample #140130 Sample #140130
Test Compound MRL (PPM) LOD (PPM) Status (PPM)
Arsenic 1.5 0.1 Pass/<LOD
Copper 0 1.5 Not Tested
Cadmium 0.5 0.1 Pass/<LOD
Chromium 2 0.3 Pass/<LOD
Lead 0.5 0.25 Pass/<LOD
Mercury 3 0.05 Pass/<LOD
Nickel 0 0.25 Not Tested

MRL - Maximum Residue Limit; LOD - Limit of Detection

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 8 of 8

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 140130-001
Client Name, Sample Details

Northern Connections / Truu Cannabis (AU-P-000247)
Lansing , MI 48910
Sample: Black Cherry Liquid Loud 200mg
License: AU-P-000247
Type: Infused Product
Method: FE60 ICPMS-MI
Metrc Test Pkg#: 1A4050300029041000003501
Metrc Source Pkg#: 1A4050300029041000003498

Test Conditions

Prepsheet ID#: MIICP 230329gMK
Temp: 22.4 °C
Baro PE: 989.2 hPa
Analyst: MK
Technician: MK

Sample ID#: 140130

Harvest/Process Date: 03/28/2023
Serving Size (g): 3.55
Date Received: 03/28/2023
Test Date: 03/29/2023
Valid Through: 03/28/2024
Report Issued: 03/30/2023

Sample #140130
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD QC Flag
Arsenic N/D 0.160 0.193 120.63 0.199 124.38
Cadmium N/D 0.160 0.182 113.75 0.195 121.88
Chromium N/D 0.480 0.544 113.33 0.554 115.42
Copper N/D 2.400 2.413 100.54 2.717 113.21
Lead N/D 0.400 0.465 116.25 0.481 120.25
Mercury N/D 0.080 0.096 120.00 0.098 122.50
Nickel N/D 0.400 0.597 149.25 0.618 154.50 HR

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 9 of 8