ORELAP     IRON Laboratories     NELAP Accredited Laboratory

ORELAP Cert No. 4092-005
OLCC No. 1002158CD2E

Oregon Compliant Marijuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 4092-005 Test Certificate #: 135887-001
Client Name, Sample Details

Oregon Grow Group
Florence, OR 97439
Sample: Duct Tape
License: 020-1011919EEBA
Type: Adult Use Flower
Method: FE04U HPLC-UV
Metrc Test Pkg#: 1A40103000223A9000000320
Metrc Source Pkg#: 1A40103000223A9000000316
***Water Activity: 0.547
***Moisture: 12.21%

Test Conditions

Prepsheet ID#: ORP220302a
Scale: XS205-OR1
Temp: 22.3 °C
Baro Pressure: 1001 hPa
Analyst: TMR
Technician: TMR

Sample ID#: 135887

Lot #: 01/08/22 Duct Tape
Batch #: 135887
Batch Weight (g): 1848.8
Harvest/Process Date: 01/08/2022
Serving Size (g): 1
Date Received: 03/01/2022
Test Date: 03/02/2022

Sample #135887
Sample #135887 Sample #135887
Test
Compounds
THC THCA CBD CBDA CBN CBG CBC THCV* CBDV Total
Cannabinoids*
Total THC Total CBD Calc Max Total
Cannabinoids*
Amount (%) 1.60 29.57 N/D 1.41 N/D 0.25 N/D N/D N/D 32.83 27.54 1.24 29.02
Amount (mg/g) 16.03 295.69 N/D 14.12 N/D 2.48 N/D N/D N/D 328.32 275.35 12.38 290.21
Amount per Serving (mg) 16.03 295.69 N\D 14.12 N\D 2.48 N\D N\D N\D 328.32 Serving Size~ (g): 1.00
LOQ (mg/g) 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5   %Decarb. THC CBD
±%RPD 0.34 2.40 1.81 16.92 3.45 5.08 12.05 +/-5% +/-5% 5 0

LOQ = Limit of Quantitation; %RPD = Relative Percent Deviation; %RSD = Relative Standard Deviation; N/D = Not Detected

*Designates values that are not currently included in the accredited scope of Iron Laboratories.

*** Designates tests that use the method FE-45. FE-45 is performed using AOAC 966.02 and 32.004-32.009. FE-45 has relative expanded (k=2) uncertainties of 1.098% for moisture, 1.754% for water activity for unprocessed plant materials, and 13.102% for water activity for infused products. Vitamin E acetate analysis has a relative expanded (k=2) uncertainty of 18.614%.

Total THC and CBD is the calculated sum of THC or CBD and the amount of THC or CBD derived from THCA or CBDA, respectively. These values are calculated by applying a molar correction factor of 0.877 to the THCA or the CBDA value. Calc Max Total Cannabinoids is the sum of Total THC, Total CBD, CBN, CBG, CBC, THCV, and CBDV.

%Decarb. THC and CBD refer to the percentage of THC or CBD relative to THCA or CBDA, respectively.

SOP FE-01-OR9 was used in accordance with OAR 333-007 for sampling. All marijuana items are sampled and tested in accordance with OAR 333-007-0300 to 333-007-490 and OAR 333-064-0100 to 333-064-0110.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Himashi Mead Iron laboratories Himashi Mead

Iron Labs Oregon complies with 2009 TNI Environmental Laboratory Standards.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401

Page 1 of 1

ORELAP     IRON Laboratories     NELAP Accredited Laboratory

ORELAP Cert No. 4092-005
OLCC No. 1002158CD2E

Oregon Compliant QC Report

Testing Accreditation #: 4092-005 Test Certificate #: 135887-001
Client Name, Sample Details

Oregon Grow Group
Florence, OR 97439
Sample: Duct Tape
License: 020-1011919EEBA
Type: Adult Use Flower
Method: FE04U HPLC-UV
Metrc Test Pkg#: 1A40103000223A9000000320
Metrc Source Pkg#: 1A40103000223A9000000316
***Water Activity: 0.547
***Moisture: 12.21%

Test Conditions

Prepsheet ID#: ORP220302a
Scale: XS205-OR1
Temp: 22.3 °C
Baro Pressure: 1001 hPa
Analyst: TMR
Technician: TMR

Sample ID#: 135887

Lot #: 01/08/22 Duct Tape
Batch #: 135887
Batch Weight (g): 1848.8
Harvest/Process Date: 01/08/2022
Serving Size (g): 1
Date Received: 03/01/2022
Test Date: 03/02/2022

Sample #135887
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD Relative Percent Difference (%) QC Flag
Cannabidivarin (CBDV) N.D. 1 0 0.00 0 0.00 0
Cannabidiolic Acid (CBDA) N.D. 11.56 10.96 94.81 9.25 80.02 16.92
Cannabigerol (CBG) N.D. 1.09 0.96 88.07 1.01 92.66 5.08
Cannabidiol (CBD) N.D. 6.5 6.01 92.46 6.12 94.15 1.81
Δ9-Tetrahydrocannabivarin (THCV) N.D. 1 0 0.00 0 0.00 0
Cannabinol (CBN) N.D. 0.44 0.59 134.09 0.57 129.55 3.45 HR
Δ9-Tetrahydrocannabinol (THC) N.D. 29.39 23.66 80.50 23.58 80.23 0.34
Cannabichromene (CBC) N.D. 0.65 0.39 60.00 0.44 67.69 12.05 LR
Tetrahydrocannabinolic acid (THCA) N.D. 57.25 52.19 91.16 53.46 93.38 2.40

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

SOP FE-01-OR9 was used in accordance with OAR 333-007 for sampling. All marijuana items are sampled and tested in accordance with OAR 333-007-0300 to 333-007-490 and OAR 333-064-0100 to 333-064-0110.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Himashi Mead Iron laboratories Himashi Mead

Iron Labs Oregon complies with 2009 TNI Environmental Laboratory Standards.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401

Page 2 of 1