IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 77802 Test Certificate #: 134797-001
Client Name, Sample Details

George Investments
Westland, MI 48186
Sample: Bossy 1:1
Type: AU Topical
Method: FE04U12 HPLC-UV

Test Conditions

Prepsheet ID#: MIP211222B
Scale: XS205-MI2
Temp: 22.1 °C
Baro Pressure: 978.3 hPa
Analyst: SKM
Technician: VU

Sample ID#: 134797

Harvest/Process Date: 12/23/2021
Serving Size (g): 131.53
Date Received: 12/23/2021
Test Date: 12/22/2021
Valid Through: 12/23/2022
Report Issued: 12/23/2021

Sample #134797
Sample #134797 Sample #134797
Test
Compounds
Δ9-THC THCA Δ8-THC CBD CBDA CBG CBGA CBN CBC CBL THCV CBDV Total
Cannabinoids*
Total THC Total CBD Calc Max Total
Cannabinoids*
Amount (%) 0.6 N/D N/D 0.7 N/D N/D N/D N/D N/D N/D N/D N/D 1.4 0.6 0.7 1.4
Amount (mg/g) 6.3 N/D N/D 6.6 N/D 0.4 N/D 0.1 0.4 N/D N/D N/D 13.8 6.3 6.6 13.8
Amount per Serving (mg) 828.639 N/D N/D 868.098 N/D 52.612 N/D 13.153 52.612 N/D N/D N/D 1,815.1 Serving Size~ (g): 131.5
LOQ (mg/g) 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07 0.07   %Decarb. THC CBD
±%RPD 3.73% 3.88% 0.96% 1.28% 1.54% 1.31% 0.55% 0.91% 3.25% 0.19% 0.40% 0.35% 100% 100%

Serving size = contents of container = 131.5347g

LOQ = Limit of Quantitation; %RPD = Relative Percent Deviation; %RSD = Relative Standard Deviation; N/D = Not Detected

*Designates values that are not currently included in the accredited scope of Iron Laboratories.

*** Designates tests that use the method FE-45. FE-45 is performed using AOAC 966.02 and 32.004-32.009.

FE-45 has relative expanded (k=2) uncertainties of 1.098% for moisture, 1.754% for water activity for unprocessed plant materials, and 13.102% for water activity for infused products.

Vitamin E acetate analysis has a relative expanded (k=2) uncertainty of 18.614%.

Total THC and CBD is the calculated sum of Δ9-THC and Δ8-THC or CBD plus the amount of THC or CBD derived from THCA or CBDA, respectively.

These values are calculated by applying a molar correction factor of 0.877 to the THCA or the CBDA value.

Calc Max Total Cannabinoids is the sum of Total THC, Total CBD, CBN, Total CBG, CBC, THCV, CBDV, and CBL.

Total CBG is calculated as CBG plus CBGA*0.878 (the molar correction factor for CBGA to CBG conversion).

%Decarb. THC and CBD refer to the percentage of Δ9-THC or CBD relative to THCA or CBDA, respectively.

This sample has not undergone random sampling and has not been tested for compliant state, batch representative testing. These results should therefore be used for research and development or quality control purposes only. Results apply to the sample as received.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

KEB - LM Iron laboratories KEB - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 1

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 134797-001
Client Name, Sample Details

George Investments
Westland, MI 48186
Sample: Bossy 1:1
Type: AU Topical
Method: FE04U12 HPLC-UV

Test Conditions

Prepsheet ID#: MIP211222B
Scale: XS205-MI2
Temp: 22.1 °C
Baro Pressure: 978.3 hPa
Analyst: SKM
Technician: VU

Sample ID#: 134797

Harvest/Process Date: 12/23/2021
Serving Size (g): 131.53
Date Received: 12/23/2021
Test Date: 12/22/2021
Valid Through: 12/23/2022
Report Issued: 12/23/2021

Sample #134797
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD Relative Percent Difference (%) QC Flag
Δ9-THC 0 5.4312 5.48174 100.93 5.69019 104.77 3.73%
THCA 0 5.46859 5.29754 96.87 5.507 100.70 3.88%
Δ8-THC 0 5.356 5.4236 101.26 5.3717 100.29 0.96%
CBD 0 5.221 5.21126 99.81 5.1449 98.54 1.28%
CBDA 0 5.35087 5.58524 104.38 5.49978 102.78 1.54%
CBG 0 4.987 5.34241 107.13 5.2731 105.74 1.31%
CBGA 0 5.18524 5.38901 103.93 5.4186 104.50 0.55%
CBN 0 4.85834 4.99862 102.89 5.04453 103.83 0.91%
CBC 0 4.89586 5.12002 104.58 4.95627 101.23 3.25%
CBCA N/A 0 0 0.00 0 0.00 0%
CBL 0 5.48 5.07587 92.63 5.08564 92.80 0.19%
THCV 0 4.91187 5.13745 104.59 5.15808 105.01 0.40%
CBDV 0 5.1027 5.14631 100.85 5.12819 100.50 0.35%

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

This sample has not undergone random sampling and has not been tested for compliant state, batch representative testing. These results should therefore be used for research and development or quality control purposes only. Results apply to the sample as received.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

KEB - LM Iron laboratories KEB - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 1