IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 77802 Test Certificate #: 122926-001
Client Name, Sample Details

JT Bills
Garden City, MI 48135
Sample: Cookies & Cream
Type: Flower
Method: FE04U HPLC-UV
***Water Activity: 0.46
***Moisture: 13.02%

Test Conditions

Prepsheet ID#: MIP200323
Scale: XS205-MI2
Temp: 21.2 °C
Baro Pressure: 982.3 hPa
Analyst: KEB
Technician: KEB/ANJ

Sample ID#: 122926

Harvest/Process Date: 03/24/2020
Serving Size (g): 1
Date Received: 03/24/2020
Test Date: 03/23/2020
Valid Through: 03/24/2021
Report Issued: 03/24/2020

Sample #122926
Sample #122926 Sample #122926
Test
Compounds
THC THCA CBD CBDA CBN CBG* CBC* THCV* CBDV* Total
Cannabinoids*
Total THC Total CBD Calc Max Total
Cannabinoids*
Amount (%) 1.0 27.5 N/D 1.5 N/D 0.2 N/D N/D N/D 30.1 25.0 1.3 26.5
Amount (mg/g) 9.6 274.6 N/D 14.9 N/D 1.8 N/D N/D N/D 300.9 250.4 13.1 265.3
Amount per Serving (mg) 9.6 274.6 N\D 14.9 N\D 1.8 N\D N\D N\D 300.9 Serving Size~ (g): 1.0
LOQ (mg/g) 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98 0.98   %Decarb. THC CBD
±%RPD 2.71 0.40 2.22 0.12 5.19 1.53 1.12 0.74 0.76 3 0%

LOQ = Limit of Quantitation; %RPD = Relative Percent Deviation; %RSD = Relative Standard Deviation; N/D = Not Detected

*Designates values that are not currently included in the accredited scope of Iron Laboratories.

*** Designates tests that use the method FE-45. FE-45 is performed using AOAC 966.02 and 32.004-32.009. FE-45 has relative expanded (k=2) uncertainties of 1.098% for moisture, 1.754% for water activity for unprocessed plant materials, and 13.102% for water activity for infused products. Vitamin E acetate analysis has a relative expanded (k=2) uncertainty of 18.614%.

Total THC and CBD is the calculated sum of THC or CBD and the amount of THC or CBD derived from THCA or CBDA, respectively. These values are calculated by applying a molar correction factor of 0.877 to the THCA or the CBDA value. Calc Max Total Cannabinoids is the sum of Total THC, Total CBD, CBN, CBG, CBC, THCV, and CBDV.

%Decarb. THC and CBD refer to the percentage of THC or CBD relative to THCA or CBDA, respectively.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

JRT LM Iron laboratories JRT LM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 6

IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 122926-001
Client Name, Sample Details

JT Bills
Garden City, MI 48135
Sample: Cookies & Cream
Type: Flower
Method: FE04U HPLC-UV
***Water Activity: 0.46
***Moisture: 13.02%

Test Conditions

Prepsheet ID#: MIP200323
Scale: XS205-MI2
Temp: 21.2 °C
Baro Pressure: 982.3 hPa
Analyst: KEB
Technician: KEB/ANJ

Sample ID#: 122926

Harvest/Process Date: 03/24/2020
Serving Size (g): 1
Date Received: 03/24/2020
Test Date: 03/23/2020
Valid Through: 03/24/2021
Report Issued: 03/24/2020

Sample #122926
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD Relative Percent Difference (%) QC Flag
Cannabidivarin (CBDV) 0 5.30476 5.54688 104.56 5.58926 105.36 0.76
Cannabidiolic Acid (CBDA) 0 5.00245 5.23793 104.71 5.24405 104.83 0.12
Cannabigerol (CBG) 0 5.37963 5.60587 104.21 5.69229 105.81 1.53
Cannabidiol (CBD) 0 4.89875 5.17809 105.70 5.29456 108.08 2.22
Δ9-Tetrahydrocannabivarin (THCV) 0 5.13115 5.28302 102.96 5.244 102.20 0.74
Cannabinol (CBN) 0 5.84655 5.75626 98.46 6.06289 103.70 5.19
Δ9-Tetrahydrocannabinol (THC) 0 5.73034 5.48268 95.68 5.63303 98.30 2.71
Cannabichromene (CBC) 0 5.6927 5.48173 96.29 5.42046 95.22 1.12
Tetrahydrocannabinolic acid (THCA) 0 5.45583 5.37614 98.54 5.35482 98.15 0.40

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

JRT LM Iron laboratories JRT LM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 6

IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

Pesticide Analysis by
Mass Spectrometer

Testing Accreditation #: 77802 Test Certificate #: 122926-001
Client Name, Sample Details

JT Bills
Garden City, MI 48135
Sample: Cookies & Cream
Type: Flower
Method: FE-52 (EN 15662 & AOAC 2007.01)

Test Conditions

Prepsheet ID#: MIPS200320a
Scale: XS205-MI1
Temp: 21.2 °C
Baro PE: 980.0 hPa
Analyst: JRT
Technician: ANJ

Sample ID#: 122926

Harvest/Process Date: 03/24/2020
Serving Size (g): 1
Date Received: 03/24/2020
Test Date: 03/20/2020
Valid Through: 03/20/2021
Report Issued: 03/24/2020

Sample #122926
Compound MRL (µg/g) LOD (µg/g) Status (µg/g)   Compound MRL (µg/g) LOD (µg/g) Status (µg/g)
Aldicarb 0.400 0.125 Pass/<LOD Abamectin**** 0.500 0.125 Pass/<LOD
Acephate 0.400 0.125 Pass/<LOD Acequinocyl 2.000 0.250 Pass/<LOD
Acetamiprid 0.200 0.125 Pass/<LOD Azoxystrobin 0.200 0.125 Pass/<LOD
Bifenazate 0.200 0.125 Pass/<LOD Bifenthrin 0.200 0.125 Pass/<LOD
Boscalid 0.400 0.125 Pass/<LOD Carbaryl 0.200 0.125 Pass/<LOD
Carbofuran 0.200 0.125 Pass/<LOD Chlorantraniliprole 0.200 0.125 Pass/<LOD
Chlorfenapyr 1.000 0.500 Pass/<LOD Chlorpyrifos 0.200 0.125 Pass/<LOD
Clofentezine 0.200 0.125 Pass/<LOD Cyfluthrin** 1.000 0.500 Pass/<LOD
Cypermethrin*** 1.000 0.500 Pass/<LOD Daminozide 1.000 0.500 Pass/<LOD
DDVP (Dichlorvos) 1.000 0.250 Pass/<LOD Diazinon 0.200 0.125 Pass/<LOD
Dimethoate 0.200 0.125 Pass/<LOD Ethoprophos 0.200 0.125 Pass/<LOD
Etofenprox 0.400 0.125 Pass/<LOD Etoxazole 0.200 0.125 Pass/<LOD
Fenoxycarb 0.200 0.125 Pass/<LOD Fenpyroximate 0.400 0.125 Pass/<LOD
Fipronil 0.400 0.125 Pass/<LOD Flonicamid 1.000 0.125 Pass/<LOD
Fludioxonil 0.400 0.125 Pass/<LOD Hexythiazox 1.000 0.125 Pass/<LOD
Imazalil 0.200 0.125 Pass/<LOD Imidacloprid 0.400 0.125 Pass/<LOD
Kresoxim Methyl 0.400 0.125 Pass/<LOD Malathion 0.200 0.125 Pass/<LOD
Metalaxyl 0.200 0.125 Pass/<LOD Methiocarb 0.200 0.125 Pass/<LOD
Methomyl 0.400 0.125 Pass/<LOD Methyl Parathion 0.200 0.125 Pass/<LOD
MGK-264‡ 0.200 0.125 Pass/<LOD Myclobutanil 0.200 0.125 Pass/<LOD
Naled 0.500 0.125 Pass/<LOD Oxamyl 1.000 0.125 Pass/<LOD
Paclobutrazol 0.400 0.125 Pass/<LOD Permethrins† 0.200 0.125 Pass/<LOD
Phosmet 0.200 0.125 Pass/<LOD Piperonyl Butoxide 10.000 1.900 Pass/<LOD
Prallethrin 0.200 0.125 Pass/<LOD Propiconazole 0.400 0.125 Pass/<LOD
Propoxur 0.200 0.125 Pass/<LOD Pyrethrins* 1.000 0.125 Pass/<LOD
Pyridaben 0.200 0.125 Pass/<LOD Spinosad***** 0.200 0.125 Pass/<LOD
Spiromesifen 0.200 0.125 Pass/<LOD Spirotetramat 0.200 0.125 Pass/<LOD
Spiroxamine‡ 0.400 0.125 Pass/<LOD Tebuconazole 0.400 0.125 Pass/<LOD
Thiacloprid 0.200 0.125 Pass/<LOD Thiamethoxam 0.200 0.125 Pass/<LOD
Trifloxystrobin 0.200 0.125 Pass/<LOD

* Pyrethrins are reported as the sum of Jasmolin I, Cinerin I, and Pyrethrin I
** Cyfluthrins are reported as the sum of isomers Cyfluthrin I, II, III, and IV
*** Cypermethrins are reported as the sum of isomers Cypermethrin I, II, III, and IV
**** Abamectin is reported as the sum of Avermectin B1a and Avermectin B1b
***** Spinosad is reported as the sum of Spinosyn A and Spinosyn D
† Permethrin and Prallethrin are reported as the sum of cis and trans isomers
‡ MGK-264 and Spiroximine are reported as the sum of isomers I and II
MRL - Maximum Residue Limit; LOD - Limit of Detection

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

JRT LM Iron laboratories JRT LM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 6

IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

Pesticide QC Report

Testing Accreditation #: 77802 Test Certificate #: 122926-001
Client Name, Sample Details

JT Bills
Garden City, MI 48135
Sample: Cookies & Cream
Type: Flower
Method: FE-52 (EN 15662 & AOAC 2007.01)

Test Conditions

Prepsheet ID#: MIPS200320a
Scale: XS205-MI1
Temp: 21.2 °C
Baro PE: 980.0 hPa
Analyst: JRT
Technician: ANJ

Sample ID#: 122926

Harvest/Process Date: 03/24/2020
Serving Size (g): 1
Date Received: 03/24/2020
Test Date: 03/20/2020
Valid Through: 03/20/2021
Report Issued: 03/24/2020

Sample #122926
Target Compound Name Method Blank (μg/g) QC Spike (μg/g) Matrix Spike (μg/g) Matrix Spike Duplicate (μg/g) MS recovery% MSD recovery% Relative Percent Difference (%) QC Flag
Acephate N.D. 1 1.03 0.994 103.00 99.40 3.56
Acequinocyl N.D. 1 0.969 1.29 96.90 129.00 28.42 HR
Acetamiprid N.D. 1 1.05 0.966 105.00 96.60 8.33
Aldicarb N.D. 1 1.01 0.997 101.00 99.70 1.30
Avermectin B1a N.D. 0.97 1.13 1.03 116.49 106.19 9.26
Azoxystrobin N.D. 1 0.956 0.906 95.60 90.60 5.37
Bifenazate N.D. 1 0.862 0.86 86.20 86.00 0.23
Bifenthrin N.D. 1 1.16 1.13 116.00 113.00 2.62
Boscalid N.D. 1 0.975 0.955 97.50 95.50 2.07
Carbaryl N.D. 1 1.08 1.09 108.00 109.00 0.92
Carbofuran N.D. 1 1.06 1.09 106.00 109.00 2.79
Chlorantraniliprole N.D. 1 0.948 0.905 94.80 90.50 4.64
Chlorfenapyr N.D. 1 0.81 0.828 81.00 82.80 2.20
Chlorpyriphos N.D. 1 1.07 1.05 107.00 105.00 1.89
Clofentezine N.D. 1 0.96 0.934 96.00 93.40 2.75
Cyfluthrin N.D. 1 0.964 1.07 96.40 107.00 10.42
Cypermethrin N.D. 1 1.1 1.13 110.00 113.00 2.69
Daminoside N.D. 1 0.982 1.03 98.20 103.00 4.77
Diazanon N.D. 1 0.991 0.947 99.10 94.70 4.54
Dichlorvos N.D. 1 1.32 1.07 132.00 107.00 20.92 HR
Dimethoate N.D. 1 1.01 1.02 101.00 102.00 0.99
Ethoprophos N.D. 1 0.82 0.81 82.00 81.00 1.23
Etofenprox N.D. 1 1.11 1.1 111.00 110.00 0.90
Etoxazole N.D. 1 1.17 1.15 117.00 115.00 1.72
Fenoxycarb N.D. 1 0.97 0.901 97.00 90.10 7.38
Fenpyroximate N.D. 1 1.04 1.01 104.00 101.00 2.93
Fipronil N.D. 1 1.11 1.1 111.00 110.00 0.90
Flonicamid N.D. 1 1.06 0.994 106.00 99.40 6.43
Fludioxonil N.D. 1 1.08 1.07 108.00 107.00 0.93
Hexythiazox N.D. 1 0.877 0.902 87.70 90.20 2.81
Imazalil N.D. 1 0.968 0.934 96.80 93.40 3.58
Imidacloprid N.D. 1 1.11 1.08 111.00 108.00 2.74
Kresoxim-methyl N.D. 1 0.881 0.848 88.10 84.80 3.82
Malathion N.D. 1 0.952 0.907 95.20 90.70 4.84
Metalaxyl N.D. 1 0.943 1.07 94.30 107.00 12.62
Methiocarb N.D. 1 0.867 0.878 86.70 87.80 1.26
Methomyl N.D. 1 1.01 1.03 101.00 103.00 1.96
MGK-264 N.D. 1 0.885 0.929 88.50 92.90 4.85
Myclobutanil N.D. 1 1.07 0.948 107.00 94.80 12.09
Naled (dibrom) N.D. 1 0.774 0.718 77.40 71.80 7.51
Oxamyl N.D. 1 1.02 0.948 102.00 94.80 7.32
Paclobutrazol N.D. 1 0.985 0.88 98.50 88.00 11.26
Parathion-methyl N.D. 1 1.02 1.17 102.00 117.00 13.70
Permethrins N.D. 1 1 1.13 100.00 113.00 12.21
Phosmet N.D. 1 0.977 0.941 97.70 94.10 3.75
Piperonyl butoxide N.D. 1 1.28 1.02 128.00 102.00 22.61 HR
Prallethrin N.D. 1 0.894 0.876 89.40 87.60 2.03
Propiconazole N.D. 1 0.905 0.918 90.50 91.80 1.43
Propoxur N.D. 1 0.988 0.926 98.80 92.60 6.48
Pyrethrin N.D. 0.65 0.557 0.445 85.69 68.46 22.36
Pyridaben N.D. 1 1.06 1.02 106.00 102.00 3.85
SpinosynA N.D. 0.84 0.663 0.628 78.93 74.76 5.42
SpinosynD N.D. 0.16 0.154 0.147 96.25 91.88 4.65
Spiromesifen N.D. 1 0.677 0.772 67.70 77.20 13.11
Spirotetramat N.D. 1 0.976 0.911 97.60 91.10 6.89
Spiroxamine N.D. 1 1.03 1 103.00 100.00 2.96
Tebuconazole N.D. 1 1.02 0.941 102.00 94.10 8.06
Thiacloprid N.D. 1 1.03 1.06 103.00 106.00 2.87
Thiamethoxam N.D. 1 0.977 0.993 97.70 99.30 1.62
Trifloxystrobin N.D. 1 0.96 0.964 96.00 96.40 0.42

N.D. = Not Detected

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 30%

R = indicates compound recovery of matrix spike was outside the methods acceptable limits. (60-120%) Low recovery could indicate there is actually more compound present than detected; while high recoveries should be scrutinized for possible fails as more compound may be detected than is actually residual on the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

JRT LM Iron laboratories JRT LM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 3 of 6

IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

Microbiology Analysis

Testing Accreditation #: 77802 Test Certificate #: 122926-001
Client Name, Sample Details

JT Bills
Garden City, MI 48135
Sample: Cookies & Cream
Type: Flower

Test Conditions

Scale: PB303-S-MI1
Temp: 23 °C
Baro Pressure: 974.1 hPa
Analyst: BCN
Technician: BCN

Sample ID#: 122926

Harvest/Process Date: 03/24/2020
Serving Size (g): 1
Date Received: 03/24/2020
Test Date: 03/22/2020
Valid Through: 03/22/2021
Report Issued: 03/23/2020

Sample #122926
Test Method MCFU (CFU/g) LOD (CFU/g) Status (CFU/g)
Total Aerobic Not Tested N/A 0 Not Tested
Yeast & Mold FE-37 (Plating enumeration) 10,001 1,000 Pass/<LOD
Bile-tolerant gram-negative bacteria Not Tested N/A 0 Not Tested
Total Coliforms FE-37 (Plating enumeration) 1,001 100 Pass/<LOD
E. Coli FE-62 (PCR) 1 10 Pass/Not Present
Salmonella FE-62 (PCR) 1 10 Pass/Not Present
Aspergillus spp. FE-62 (PCR) 1 10 Pass/Not Present

E. coli test screens exclusively for Shiga toxin-producing E. coli. TNTC values for yeast and mold are >150,000 CFU/g. TNTC values for total coliforms are >15,000 CFU/g.

TNTC = Too Numerous To Count. Maximum Colony Forming Units (MCFU) represents the minimum value that a test would need to achieve in order to be considered a failed result (if applicable). LOD is the Limit of Detection for the method. CFU/g = Colony Forming Units per gram. Aspergillus spp. consists of A. flavus, A. fumigatus, A. niger, and A. terreus.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 4 of 6

IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

Bio Analysis by
Microscopic Visual Inspection

Testing Accreditation #: 77802 Test Certificate #: 122926-001
Client Name, Sample Details

JT Bills
Garden City, MI 48135
Sample: Cookies & Cream
Type: Flower
Method: FE02 Microscope Dissection

Test Conditions

Analyst: ARH
Technician: ARH

Sample ID#: 122926

Harvest/Process Date: 03/24/2020
Serving Size (g): 1
Date Received: 03/24/2020
Test Date: 03/22/2020
Valid Through: 03/22/2021
Report Issued: 03/24/2020

Sample #122926
Sample #122926 Sample #122926
Severity Rating
Mold and Mildew 0 Pass
Mites (not Russet) 0 Pass
Russet Mites 0 Pass
Thrips 0 Pass
Aphids 0 Pass
Other Pests 0 Pass
Other Organic Matter 0 Pass
Inorganic Matter 0 Pass
Total Organic Foreign Matter <2% Pass
Inorganic Foreign Matter 0% Pass
Stem Material <5% Pass
Severity Rating Key
Correlating %FM ≤2% FM >2% FM
Severity Rating 0 None 1 Mild 2 Moderate 3 Severe Units
Mold and Mildew <2 2 3 4+ Locations/g
Mites (not russet) <1 1-5 6-10 11+ Amount/g
Russet Mites <1 1-10 11-50 51+ Amount/g
Thrips <1 1-3 4-5 6+ Amount/g
Aphids <1 1 2-4 5+ Amount/g
Other Pests <1 1-5 6-10 11+ Amount/g
Other Organic Matter <1 1-5 6-10 11+ Amount/g
Inorganic Matter 0 >0 Amount/g

In compliance with the MMFLA regulation, the action limits for foreign matter are as follows; no more that 2% organic matter, 5% stem material, and no presence of inorganic matter. Percent foreign contamination is based off of total surface area.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 5 of 6

IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

Heavy Metals Analysis

Testing Accreditation #: 77802 Test Certificate #: 122926-001
Client Name, Sample Details

JT Bills
Garden City, MI 48135
Sample: Cookies & Cream
Type: Flower
Method: FE60 ICPMS-MI

Test Conditions

Prepsheet ID#: MIICP200317fMK
Temp: 19.7 °C
Baro PE: 982.8 hPa
Analyst: TAC
Technician: MK

Sample ID#: 122926

Harvest/Process Date: 03/24/2020
Serving Size (g): 1
Date Received: 03/24/2020
Test Date: 03/19/2020
Valid Through: 03/19/2021
Report Issued: 03/20/2020

Sample #122926
Sample #122926 Sample #122926
Test Compound MRL (PPM) LOD (PPM) Status (PPM)
Arsenic 0.2 0.1 Pass/<LOD
Copper 0 1.5 Not Tested
Cadmium 0.2 0.1 Pass/<LOD
Chromium 0.6 0.3 Pass/<LOD
Lead 0.5 0.25 Pass/<LOD
Mercury 0.1 0.05 Pass/<LOD
Nickel 0.5 0.25 Pass/<LOD

The testing requirements set by the MRA for copper and nickel will not be effective until July 1, 2020.

MRL - Maximum Residue Limit; LOD - Limit of Detection

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 6 of 6

IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 122926-001
Client Name, Sample Details

JT Bills
Garden City, MI 48135
Sample: Cookies & Cream
Type: Flower
Method: FE60 ICPMS-MI

Test Conditions

Prepsheet ID#: MIICP200317fMK
Temp: 19.7 °C
Baro PE: 982.8 hPa
Analyst: TAC
Technician: MK

Sample ID#: 122926

Harvest/Process Date: 03/24/2020
Serving Size (g): 1
Date Received: 03/24/2020
Test Date: 03/19/2020
Valid Through: 03/19/2021
Report Issued: 03/20/2020

Sample #122926
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD QC Flag
Arsenic N/D 0.160 0.158 98.75 0.158 98.75
Cadmium N/D 0.160 0.257 160.63 0.260 162.50 HRHR
Chromium N/D 0.480 0.683 142.29 0.649 135.21
Copper N/D 2.400 3.844 160.17 2.292 95.50 HRQ
Lead N/D 0.400 0.465 116.25 0.456 114.00
Mercury N/D 0.080 0.123 153.75 0.125 156.25 HRHR
Nickel N/D 0.400 0.702 175.50 0.662 165.50 HRHR

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 7 of 6