IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

Microbiology Analysis

Testing Accreditation #: 77802 Test Certificate #: 122012-001
Client Name, Sample Details

Evolution Grow Company
Ann Arbor, AK 48104
Sample: Sample 1 Micro
License: PT-19-027748
Type: Flower

Test Conditions

Scale: See prepsheet(Plating)/PB303-S-MI1(PCR)
Analyst: ACR
Technician: See prepsheet(Plating)/BCN(PCR)

Sample ID#: 122012

Harvest/Process Date: 03/03/2020
Date Received: 03/03/2020
Test Date: 03/03/2020
Valid Through: 03/03/2021
Report Issued: 03/03/2020

Sample #122012
Test Method MCFU (CFU/g) LOD (CFU/g) Status (CFU/g)
Total Aerobic Not Tested N/A 0 Not Tested
Yeast & Mold FE-37 (Plating enumeration) 10,001 1,000 Pass/2,000
Bile-tolerant gram-negative bacteria Not Tested N/A 0 Not Tested
Total Coliforms FE-37 (Plating enumeration) 1,001 100 Pass/<LOD
E. Coli FE-62 (PCR) 1 10 Pass/Not Present
Salmonella FE-62 (PCR) 1 10 Pass/Not Present
Aspergillus spp. FE-62 (PCR) 1 10 Pass/Not Present

E. coli test screens exclusively for Shiga toxin-producing E. coli. TNTC values for yeast and mold are >150,000 CFU/g. TNTC values for total coliforms are >15,000 CFU/g.

TNTC = Too Numerous To Count. Maximum Colony Forming Units (MCFU) represents the minimum value that a test would need to achieve in order to be considered a failed result (if applicable). LOD is the Limit of Detection for the method. CFU/g = Colony Forming Units per gram. Aspergillus spp. consists of A. flavus, A. fumigatus, A. niger, and A. terreus.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 1