IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 77802 Test Certificate #: 114920-001
Client Name, Sample Details

Dian Younan
Troy, MI 48085
Sample: Girl Scout Thin Mint
Type: Flower
Method: FE04U HPLC1100-1
***Moisture: 18.03%

Test Conditions

Prepsheet ID#: MIP190207
Scale: XS205-MI2
Temp: 21.3 °C
Baro PE: 987.0 hPa
Analyst: JRT
Technician: JRT

Sample ID#: 114920

Harvest/Process Date: 02/08/2019
Serving Size (g): 1
Date Received: 02/08/2019
Test Date: 02/08/2019
Valid Through: 02/08/2020

Sample #114920
Sample #114920 Sample #114920
Test
Compounds
THC THCA CBD CBDA CBN CBG* CBC* THCV* CBDV* Total
Cannabinoids*
Total THC Total CBD Calc Max Total
Cannabinoids*
Amount (%) 1.1 21.9 0 1.3 0 0 0 0 0 24.2 20.3 1.1 21.4
Amount (mg/g) 10.7 218.7 N/D 12.5 N/D N/D N/D N/D N/D 241.9 202.5 11.0 213.5
Amount per Serving (mg) 10.7 218.7 N/D 12.5 N/D N/D N/D N/D N/D 241.9 Serving Size~ (g): 1.0
LOQ (mg/g) 1 1 1 1 1 1 1 1 1   %Decarb. THC CBD
±%RPD 2.7 2.5 0.4 5.6 0.9 0.9 7.2 2.8 0.1 5 0%

LOQ = Limit of Quantitation; %RPD = Relative Percent Deviation; %RSD = Relative Standard Deviation; N/D = Not Detected

*Designates values that are not currently included in the accredited scope of Iron Laboratories Michigan.

*** Designates tests that use the method FE-45.

Total THC and CBD is the calculated sum of THC or CBD and the amount of THC or CBD derived from THCA or CBDA, respectively. These values are calculated by applying a molar correction factor of 0.877 to the THCA or the CBDA value. Calc Max Total Cannabinoids is the sum of Total THC, Total CBD, CBN, CBG, CBC, THCV, and CBDV.

%Decarb. THC and CBD refers to the percentage of THC or CBD relative to THCA or CBDA, respectively.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ACR - LM Iron laboratories ACR - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 2

IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 114920-001
Client Name, Sample Details

Dian Younan
Troy, MI 48085
Sample: Girl Scout Thin Mint
Type: Flower
Method: FE04U HPLC1100-1
***Moisture: 18.03%

Test Conditions

Prepsheet ID#: MIP190207
Scale: XS205-MI2
Temp: 21.3 °C
Baro PE: 987.0 hPa
Analyst: JRT
Technician: JRT

Sample ID#: 114920

Harvest/Process Date: 02/08/2019
Serving Size (g): 1
Date Received: 02/08/2019
Test Date: 02/08/2019
Valid Through: 02/08/2020

Sample #114920
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD Relative Percent Difference (%) QC Flag
Cannabidivarin (CBDV) 0 1.948628295 2.082753111 106.88 2.081363939 106.81 0.07%
Cannabidiolic Acid (CBDA) 0 5.403870479 5.400138506 99.93 5.712015155 105.70 5.61%
Cannabigerol (CBG) 0 4.043111936 4.136881996 102.32 4.172408349 103.20 0.86%
Cannabidiol (CBD) 0 5.613972453 5.736017989 102.17 5.757781221 102.56 0.38%
Δ9-Tetrahydrocannabivarin (THCV) 0 2.713366661 2.790336414 102.84 2.870176357 105.78 2.82%
Cannabinol (CBN) 0 5.144562544 5.184508717 100.78 5.231885731 101.70 0.91%
Δ9-Tetrahydrocannabinol (THC) 0 6.800124294 6.868764876 101.01 7.055641399 103.76 2.68%
Cannabichromene (CBC) 0 6.086376266 6.387726758 104.95 6.865409372 112.80 7.21%
Tetrahydrocannabinolic acid (THCA) 0 5.801233696 6.111698258 105.35 5.961610581 102.76 2.49%

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ACR - LM Iron laboratories ACR - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390