ORELAPIRON LaboratoriesNELAP Accredited Laboratory

ORELAP Cert No. 4092-002
OLCC No. 1002158CD2E

Hemp Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 4092-002 Test Certificate #: 114517-001
Client Name, Sample Details

Black Tie CBD
Myrtle Creek, OR 97457
Sample: The Jack (2)
License: AG-R1045922IHH
Type: Industrial Hemp
Method: FE58RD HPLC1100-OR1
***Moisture: 10.93%

Test Conditions

Scale: XS205-OR1
Temp: 21.7 °C
Baro Pressure: 1015 hPa
Analyst: HRM
Technician: EDT

Sample ID#: 114517

Lot #: R&D
Batch #: 114517
Harvest/Process Date: 01/16/2019
Date Received: 01/17/2019
Test Date: 01/21/2019

Sample #114517
Sample #114517 Sample #114517
Test
Compounds
CBDV CBDA CBD CBC CBG CBN THCA THCV ∆9-THC Total Cannabinoids
Amount N/D 21.78% 0.83% 0.11% 0.09% N/D 1.02% N/D N/D 23.83%
LOQ 0.05% 0.05% 0.05% 0.05% 0.05% 0.05% 0.05% 0.05% 0.05% Total CBD
Uncertainty ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD 19.93%

THC = Delta-9-THC

LOQ = Limit of Quantitation

RPD is relative percent difference between the LCS and LCS duplicate.

%RPD = Relative Percent Difference; Min. Value = Minimum Detectable Amount, CFU = Colony Forming Units, N/D = Not Detected

*** Designated tests that use the method FE-45.

This sample has not been tested according to OAR 333-007. These results should therefore be used for research and development or quality control purposes only.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Joseph Rutowski Iron laboratories Joseph Rutowski

Iron Labs Oregon complies with 2009 TNI Environmental Laboratory Standards.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401

Page 1 of 5

ORELAPIRON LaboratoriesNELAP Accredited Laboratory

ORELAP Cert No. 4092-002
OLCC No. 1002158CD2E

Pesticide Analysis by
Mass Spectrometer

Testing Accreditation #: 4092-002 Test Certificate #: 114517-001
Client Name, Sample Details

Black Tie CBD
Myrtle Creek, OR 97457
Sample: The Jack (2)
License: AG-R1045922IHH
Type: Industrial Hemp
Method: FE-52 (EN 15662 & AOAC 2007.01)

Test Conditions

Prepsheet ID#: ORPS190123a
Scale: Veritas-OR1
Temp: 21.4 °C
Baro PE: 1014 hPa
Analyst: JDM
Technician: JDM

Sample ID#: 114517

Lot #: R&D
Batch #: 114517
Harvest/Process Date: 01/16/2019
Date Received: 01/17/2019
Test Date: 01/24/2019

Sample #114517
Compound MRL (µg/g) LOD (µg/g) Status (µg/g)   Compound MRL (µg/g) LOD (µg/g) Status (µg/g)
Aldicarb 0.400 0.120 Pass/<LOD Abamectin**** 0.500 0.120 Pass/<LOD
Acephate 0.400 0.120 Pass/<LOD Acequinocyl 2.000 0.239 Pass/<LOD
Acetamiprid 0.200 0.120 Pass/<LOD Azoxystrobin 0.200 0.120 Pass/<LOD
Bifenazate 0.200 0.120 Pass/<LOD Bifenthrin 0.200 0.120 Pass/<LOD
Boscalid 0.400 0.120 Pass/<LOD Carbaryl 0.200 0.120 Pass/<LOD
Carbofuran 0.200 0.120 Pass/<LOD Chlorantraniliprole 0.200 0.120 Pass/<LOD
Chlorfenapyr 1.000 0.478 Pass/<LOD Chlorpyrifos 0.200 0.120 Pass/<LOD
Clofentezine 0.200 0.120 Pass/<LOD Cyfluthrin** 1.000 0.478 Pass/<LOD
Cypermethrin*** 1.000 0.478 Pass/<LOD Daminozide 1.000 0.120 Pass/<LOD
DDVP (Dichlorvos) 1.000 0.239 Pass/<LOD Diazinon 0.200 0.120 Pass/<LOD
Dimethoate 0.200 0.120 Pass/<LOD Ethoprophos 0.200 0.120 Pass/<LOD
Etofenprox 0.400 0.120 Pass/<LOD Etoxazole 0.200 0.120 Pass/<LOD
Fenoxycarb 0.200 0.120 Pass/<LOD Fenpyroximate 0.400 0.120 Pass/<LOD
Fipronil 0.400 0.120 Pass/<LOD Flonicamid 1.000 0.120 Pass/<LOD
Fludioxonil 0.400 0.120 Pass/<LOD Hexythiazox 1.000 0.120 Pass/<LOD
Imazalil 0.200 0.120 Pass/<LOD Imidacloprid 0.400 0.120 Pass/<LOD
Kresoxim Methyl 0.400 0.120 Pass/<LOD Malathion 0.200 0.120 Pass/<LOD
Metalaxyl 0.200 0.120 Pass/<LOD Methiocarb 0.200 0.120 Pass/<LOD
Methomyl 0.400 0.120 Pass/<LOD Methyl Parathion 0.200 0.120 Pass/<LOD
MGK-264‡ 0.200 0.120 Pass/<LOD Myclobutanil 0.000 0.120 Pass/<LOD
Naled 0.500 0.120 Pass/<LOD Oxamyl 1.000 0.120 Pass/<LOD
Paclobutrazol 0.400 0.120 Pass/<LOD Permethrins† 0.200 0.120 Pass/<LOD
Phosmet 0.200 0.120 Pass/<LOD Piperonyl Butoxide 2.000 0.120 Pass/<LOD
Prallethrin 0.200 0.120 Pass/<LOD Propiconazole 0.400 0.120 Pass/<LOD
Propoxur 0.200 0.120 Pass/<LOD Pyrethrins* 1.000 0.120 Pass/<LOD
Pyridaben 0.200 0.120 Pass/<LOD Spinosad***** 0.200 0.120 Pass/<LOD
Spiromesifen 0.200 0.120 Pass/<LOD Spirotetramat 0.200 0.120 Pass/<LOD
Spiroxamine‡ 0.400 0.120 Pass/<LOD Tebuconazole 0.400 0.120 Pass/<LOD
Thiacloprid 0.200 0.120 Pass/<LOD Thiamethoxam 0.200 0.120 Pass/<LOD
Trifloxystrobin 0.200 0.120 Pass/<LOD

* Pyrethrins are reported as the sum of Jasmolin I, Cinerin I, and Pyrethrin I
** Cyfluthrins are reported as the sum of isomers Cyfluthrin I, II, III, and IV
*** Cypermethrins are reported as the sum of isomers Cypermethrin I, II, III, and IV
**** Abamectin is reported as the sum of Avermectin B1a and Avermectin B1b
***** Spinosad is reported as the sum of Spinosyn A and Spinosyn D
† Permethrin and Prallethrin are reported as the sum of cis and trans isomers
‡ MGK-264 and Spiroximine are reported as the sum of isomers I and II
MRL - Maximum Residue Limit; LOD - Limit of Detection

This sample has not been tested according to OAR 333-007. These results should therefore be used for research and development or quality control purposes only.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Joseph Rutowski Iron laboratories Joseph Rutowski

Iron Labs Oregon complies with 2009 TNI Environmental Laboratory Standards.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401

Page 2 of 5

ORELAPIRON LaboratoriesNELAP Accredited Laboratory

ORELAP Cert No. 4092-002
OLCC No. 1002158CD2E

Pesticide QC Report

Testing Accreditation #: 4092-002 Test Certificate #: 114517-001
Client Name, Sample Details

Black Tie CBD
Myrtle Creek, OR 97457
Sample: The Jack (2)
License: AG-R1045922IHH
Type: Industrial Hemp
Method: FE-52 (EN 15662 & AOAC 2007.01)

Test Conditions

Prepsheet ID#: ORPS190123a
Scale: Veritas-OR1
Temp: 21.4 °C
Baro PE: 1014 hPa
Analyst: JDM
Technician: JDM

Sample ID#: 114517

Lot #: R&D
Batch #: 114517
Harvest/Process Date: 01/16/2019
Date Received: 01/17/2019
Test Date: 01/24/2019

Sample #114517
Target Compound Name Method Blank (μg/g) QC Spike (μg/g) Matrix Spike (μg/g) Matrix Spike Duplicate (μg/g) MS recovery% MSD recovery% Relative Percent Difference (%) QC Flag
Acephate N.D. 1 0.911 0.968 91.10 96.80 6.07
Acequinocyl N.D. 1 0.765 0.705 76.50 70.50 8.16
Acetamiprid N.D. 1 0.91 0.88 91.00 88.00 3.35
Aldicarb N.D. 1 0.979 0.937 97.90 93.70 4.38
Avermectin B1a N.D. 0.97 0.851 0.939 87.73 96.80 9.83
Azoxystrobin N.D. 1 0.714 0.71 71.40 71.00 0.56
Bifenazate N.D. 1 0.605 0.719 60.50 71.90 17.22 LR
Bifenthrin N.D. 1 0.738 0.81 73.80 81.00 9.30
Boscalid N.D. 1 0.668 0.77 66.80 77.00 14.19 LR
Carbaryl N.D. 1 0.926 0.913 92.60 91.30 1.41
Carbofuran N.D. 1 0.9 0.867 90.00 86.70 3.74
Chlorantraniliprole N.D. 1 0.6 0.702 60.00 70.20 15.67 LR
Chlorfenapyr N.D. 1 0.854 0.802 85.40 80.20 6.28
Chlorpyriphos N.D. 1 0.86 0.939 86.00 93.90 8.78
Clofentezine N.D. 1 0.565 0.684 56.50 68.40 19.06 LR
Cyfluthrin N.D. 1 0.694 0.788 69.40 78.80 12.69 LR
Cypermethrin N.D. 1 0.746 0.857 74.60 85.70 13.85
Daminoside N.D. 1 0.426 0.468 42.60 46.80 9.40 LR
Diazanon N.D. 1 0.562 0.668 56.20 66.80 17.24 LR
Dichlorvos N.D. 1 0.843 0.857 84.30 85.70 1.65
Dimethoate N.D. 1 0.909 0.857 90.90 85.70 5.89
Ethoprophos N.D. 1 0.703 0.674 70.30 67.40 4.21 LR
Etofenprox N.D. 1 0.827 0.81 82.70 81.00 2.08
Etoxazole N.D. 1 0.881 0.944 88.10 94.40 6.90
Fenoxycarb N.D. 1 0.624 0.746 62.40 74.60 17.81 LR
Fenpyroximate N.D. 1 0.966 0.959 96.60 95.90 0.73
Fipronil N.D. 1 0.939 0.95 93.90 95.00 1.16
Flonicamid N.D. 1 0.855 0.829 85.50 82.90 3.09
Fludioxonil N.D. 1 1 0.94 100.00 94.00 6.19
Hexythiazox N.D. 1 0.592 0.545 59.20 54.50 8.27 LR
Imazalil N.D. 1 0.633 0.755 63.30 75.50 17.58 LR
Imidacloprid N.D. 1 0.83 0.895 83.00 89.50 7.54
Kresoxim-methyl N.D. 1 0.569 0.674 56.90 67.40 16.89 LR
Malathion N.D. 1 0.653 0.789 65.30 78.90 18.86 LR
Metalaxyl N.D. 1 0.73 0.813 73.00 81.30 10.76
Methiocarb N.D. 1 0.838 0.762 83.80 76.20 9.50
Methomyl N.D. 1 0.713 0.887 71.30 88.70 21.75 Q
MGK-264 N.D. 1 0.573 0.68 57.30 68.00 17.08 LR
Myclobutanil N.D. 1 0.654 0.803 65.40 80.30 20.45 LRQ
Naled (dibrom) N.D. 1 0.692 0.647 69.20 64.70 6.72 LR
Oxamyl N.D. 1 0.839 0.839 83.90 83.90 0.00
Paclobutrazol N.D. 1 0.638 0.764 63.80 76.40 17.97 LR
Parathion-methyl N.D. 1 0.836 0.832 83.60 83.20 0.48
Permethrins N.D. 1 0.865 0.88 86.50 88.00 1.72
Phosmet N.D. 1 0.642 0.768 64.20 76.80 17.87 LR
Piperonyl butoxide N.D. 1 0.925 0.961 92.50 96.10 3.82
Prallethrin N.D. 1 0.543 0.656 54.30 65.60 18.85 LR
Propiconazole N.D. 1 0.653 0.723 65.30 72.30 10.17 LR
Propoxur N.D. 1 0.986 0.954 98.60 95.40 3.30
Pyrethrin N.D. 0.65 0.428 0.476 65.85 73.23 10.62 LR
Pyridaben N.D. 1 0.815 0.863 81.50 86.30 5.72
SpinosynA N.D. 0.84 0.619 0.702 73.69 83.57 12.57
SpinosynD N.D. 0.16 0.135 0.133 84.38 83.13 1.49
Spiromesifen N.D. 1 0.365 0.385 36.50 38.50 5.33 LR
Spirotetramat N.D. 1 0.724 0.742 72.40 74.20 2.46
Spiroxamine N.D. 1 0.704 0.808 70.40 80.80 13.76
Tebuconazole N.D. 1 0.595 0.744 59.50 74.40 22.26 LRQ
Thiacloprid N.D. 1 0.776 0.8 77.60 80.00 3.05
Thiamethoxam N.D. 1 0.647 0.752 64.70 75.20 15.01 LR
Trifloxystrobin N.D. 1 0.84 0.838 84.00 83.80 0.24

N.D. = Not Detected

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 30%

R = indicates compound recovery of matrix spike was outside the methods acceptable limits. (60-120%) Low recovery could indicate there is actually more compound present than detected; while high recoveries should be scrutinized for possible fails as more compound may be detected than is actually residual on the sample.

This sample has not been tested according to OAR 333-007. These results should therefore be used for research and development or quality control purposes only.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Joseph Rutowski Iron laboratories Joseph Rutowski

Iron Labs Oregon complies with 2009 TNI Environmental Laboratory Standards.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401

Page 3 of 5

IRON Laboratories

Terpene Report by
Mass Spectrometer

Test Certificate #: 114517-001
Client Name, Sample Details

Black Tie CBD
Myrtle Creek, OR 97457
Sample: The Jack (2)
License: AG-R1045922IHH
Type: Industrial Hemp
Method: SOP FE-44-OR3

Test Conditions

Scale: XS205-OR1
Temp: 19.1 °C
Baro Pressure: 1001 hPa
Analyst: HRM
Technician: HRM

Sample ID#: 114517

Lot #: R&D
Batch #: 114517
Harvest/Process Date: 01/16/2019
Date Received: 01/17/2019
Test Date: 01/25/2019

Sample #114517

Mono Terpenes

Weight Percentage Dry Matter (wt/wt%)

α-Pinene:

0.110 %

β-Ocimene:

0.070 %

Camphene:

N/D

Eucalyptol (1,8-Cineol):

N/D

Sabinene:

N/D

γ-Terpinene:

N/D

Myrcene:

0.330 %

α-Terpinolene:

0.070 %

β-Pinene:

0.090 %

Linalool:

0.020 %

∆3-Carene:

N/D

Fenchone:

N/D

α-Terpinene:

0.020 %

Fenchol:

0.020 %

Ocimene:

N/D

Isopulegol:

N/D

Limonene:

0.080 %

Geraniol:

N/D

4-Cymene:

N/D

Sequi Terpenes

Weight Percentage Dry Matter (wt/wt%)

β-Caryophyllene:

0.140 %

α-Humulene:

0.070 %

Nerolidol 1:

N/D

Nerolidol 2:

N/D

Guaiol:

0.120 %

Caryophyllene Oxide:

0.040 %

α-Bisabolol:

0.100 %

Other Terpenes

Total: 1.280%
a-Phellandrene = 0.10 % a-Terpineol = 0.02 % Valencene = 0.06 %

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Joseph Rutowski Iron laboratories Joseph Rutowski

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401

Page 4 of 5

IRON Laboratories

Heavy Metals Analysis

Test Certificate #: 114517-001
Client Name, Sample Details

Black Tie CBD
Myrtle Creek, OR 97457
Sample: The Jack (2)
License: AG-R1045922IHH
Type: Industrial Hemp
Method: FE60 ICPMS-MI

Test Conditions

Analyst: JER
Technician: TAC

Sample ID#: 114517

Lot #: R&D
Batch #: 114517
Harvest/Process Date: 01/16/2019
Date Received: 01/17/2019
Report Issued: 02/12/2019

Sample #114517
Sample #114517 Sample #114517
Test Compound MRL (PPM) LOD (PPM) Status (PPM)
Arsenic 0.2 0.05 Pass/<LOD
Copper Not Tested
Cadmium 0.2 0.05 Pass/0.155
Chromium 0.6 0.05 Pass/0.644
Lead 0.5 0.05 Pass/0.129
Mercury 0.1 0.05 Pass/<LOD
Nickel Not Tested

MRL - Maximum Residue Limit; LOD - Limit of Detection

This sample has not been tested according to OAR 333-007. These results should therefore be used for research and development or quality control purposes only.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 5 of 5