ORELAPIRON LaboratoriesNELAP Accredited Laboratory

ORELAP Cert No. 4092-002
OLCC No. 1002158CD2E

Marijuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 4092-002 Test Certificate #: 114221-001
Client Name, Sample Details

Octo Consulting LLC
Eugene, OR 97403
Sample: 1-8-18-AA
Type: Extract
Method: FE04C-OR4 HPLC1100-OR1

Test Conditions

Scale: XS205-OR1
Temp: 21.6 °C
Baro Pressure: 995 hPa
Analyst: HRM
Technician: EDT

Sample ID#: 114221

Lot #: R & D Only
Batch #: 114221
Harvest/Process Date: 01/08/2018
Serving Size (g): 0.1
Package Weight (g):1
Date Received: 01/09/2019
Test Date: 01/09/2019

Sample #114221
Sample #114221 Sample #114221
Test
Compounds
CBDV CBDA CBD CBC CBG CBN THC THCA THCV   Calc. Avg
Avg. Amount 11.28 mg/g 10.48 mg/g 803.16 mg/g 50.48 mg/g 20.52 mg/g 3.16 mg/g 27.44 mg/g N/D N/D CBD 812.35 mg/g
LOQ 0.05 mg/g 0.05 mg/g 0.05 mg/g 0.05 mg/g 0.05 mg/g 0.05 mg/g 0.05 mg/g 0.05 mg/g 0.05 mg/g THC 27.44 mg/g
Amount per Serving~ 1.13 mg/srv 1.05 mg/srv 80.32 mg/srv 5.05 mg/srv 2.05 mg/srv 0.32 mg/srv 2.74 mg/srv N/D N/D Serving Size~ (g): 0.10 g
Uncertainty ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD ±5% RPD

LOQ = Limit of Quantitation

RPD is relative percent difference between the LCS and LCS duplicate.

%RPD = Relative Percent Difference; Min. Value = Minimum Detectable Amount, CFU = Colony Forming Units, N/D = Not Detected

*** Designated tests that use the method FE-45.

Total CBD or THC is the calculated sum of CBD or THC and the amount of CBD or THC derived from CBDA or THCA, respectively. These values are calculated by adding a molar correction factor of 0.877 to the CBDA or THCA value.

Calc. Avg. is the calculated average of total CBD or total THC for all increments tested.

This sample has not been tested according to OAR 333-007. These results should therefore be used for research and development or quality control purposes only.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

Joseph Rutowski Iron laboratories Joseph Rutowski

Iron Labs Oregon complies with 2009 TNI Environmental Laboratory Standards.

Tested by Iron Laboratories Oregon, 71 Centennial Loop Suite D Eugene, OR 97401

Page 1 of 1