IRON LaboratoriesPJLA

ISO/IEC 17025:2005 Accredited

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 77802 Test Certificate #: 111468-001
Client Name, Sample Details

Peregrine Manufacturing
Michigan Center, MI 49254
Sample: HH Distillate
Type: Medical Flower
Method: FE04P HPLC1100-1

Test Conditions

Scale: XS205-MI2
Temp: 22 °C
Baro Pressure: 988.6 hPa
Analyst: MEH
Technician: JRT

Sample ID#: 111468

Harvest/Process Date: 09/12/2018
Serving Size (g): 1
Date Received: 09/11/2018
Test Date: 09/12/2018
Valid Through: 09/12/2019
Report Issued: 09/13/2018

Sample #111468
Sample #111468 Sample #111468
Test
Compounds
CBDV* CBDA CBD CBC* CBG* CBN THC THCA THCV* Calc. Max THC Calc. Max CBD
Amount N/D N/D N/D 2.6% 3.0% 1.2% 82.4% N/D 0.5% 82.4% 0.0%
LOQ 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% 0.3% 0.3%
Uncertainty ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD ±5% RSD

LOQ = Limit of Quantitation; %RSD = Relative Standard Deviation; N/D = Not Detected

*Designates compounds that are not currently included in Iron Laboratories' accredited scope.

*** Designates tests that use the method FE-45.

Calc. Max is the calculated sum of CBD or THC and the amount of CBD or THC derived from CBDA or THCA, respectively. These values are calculated by applying a molar correction factor of 0.877 to the CBDA or THCA value.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Iron Laboratories, LLC is an ISO/IEC 17025:2005 Testing Laboratory laboratory, accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 4

IRON Laboratories

Pesticide Analysis by
Mass Spectrometer

Test Certificate #: 111468-001
Client Name, Sample Details

Peregrine Manufacturing
Michigan Center, MI 49254
Sample: HH Distillate
Type: Medical Flower
Method: FE-52 (EN 15662 & AOAC 2007.01)

Test Conditions

Scale: XS205-MI1
Temp: 22.7 °C
Baro Pressure: 986.1 hPa
Analyst: JER
Technician: JSS

Sample ID#: 111468

Harvest/Process Date: 09/12/2018
Serving Size (g): 1
Date Received: 09/11/2018
Test Date: 09/22/2018
Valid Through: 09/22/2019
Report Issued: 09/25/2018

Sample #111468
Compound MRL (µg/g) LOD (µg/g) Status (µg/g)   Compound MRL (µg/g) LOD (µg/g) Status (µg/g)
Aldicarb 0.400 0.125 Pass/<LOD Abamectin**** 0.500 0.125 Pass/<LOD
Acephate 0.400 0.125 Pass/<LOD Acequinocyl 2.000 0.251 Pass/<LOD
Acetamiprid 0.200 0.125 Pass/<LOD Azoxystrobin 0.200 0.125 Pass/<LOD
Bifenazate 0.200 0.125 Pass/<LOD Bifenthrin 0.200 0.125 Pass/<LOD
Boscalid 0.400 0.125 Pass/<LOD Carbaryl 0.200 0.125 Pass/<LOD
Carbofuran 0.200 0.125 Pass/<LOD Chlorantraniliprole 0.200 0.125 Pass/<LOD
Chlorfenapyr 1.000 0.502 Pass/<LOD Chlorpyrifos 0.200 0.125 Pass/<LOD
Clofentezine 0.200 0.125 Pass/<LOD Cyfluthrin** 1.000 0.502 Pass/<LOD
Cypermethrin*** 1.000 0.502 Pass/<LOD Daminozide 1.000 0.125 Pass/<LOD
DDVP (Dichlorvos) 1.000 0.251 Pass/<LOD Diazinon 0.200 0.125 Pass/<LOD
Dimethoate 0.200 0.125 Pass/<LOD Ethoprophos 0.200 0.125 Pass/<LOD
Etofenprox 0.400 0.125 Pass/<LOD Etoxazole 0.200 0.125 Pass/<LOD
Fenoxycarb 0.200 0.125 Pass/<LOD Fenpyroximate 0.400 0.125 Pass/<LOD
Fipronil 0.400 0.125 Pass/<LOD Flonicamid 1.000 0.125 Pass/<LOD
Fludioxonil 0.400 0.125 Pass/<LOD Hexythiazox 1.000 0.125 Pass/<LOD
Imazalil 0.200 0.125 Pass/<LOD Imidacloprid 0.400 0.125 Pass/<LOD
Kresoxim Methyl 0.400 0.125 Pass/<LOD Malathion 0.200 0.125 Pass/<LOD
Metalaxyl 0.200 0.125 Pass/<LOD Methiocarb 0.200 0.125 Pass/<LOD
Methomyl 0.400 0.125 Pass/<LOD Methyl Parathion 0.200 0.125 Pass/<LOD
MGK-264‡ 0.200 0.125 Pass/<LOD Myclobutanil 0.200 0.125 Pass/<LOD
Naled 0.500 0.125 Pass/<LOD Oxamyl 1.000 0.125 Pass/<LOD
Paclobutrazol 0.400 0.125 Pass/<LOD Permethrins† 0.200 0.125 Pass/<LOD
Phosmet 0.200 0.125 Pass/<LOD Piperonyl Butoxide 2.000 0.125 Pass/<LOD
Prallethrin 0.200 0.125 Pass/<LOD Propiconazole 0.400 0.125 Pass/<LOD
Propoxur 0.200 0.125 Pass/<LOD Pyrethrins* 1.000 0.125 Pass/<LOD
Pyridaben 0.200 0.125 Pass/<LOD Spinosad***** 0.200 0.125 Pass/<LOD
Spiromesifen 0.200 0.125 Pass/<LOD Spirotetramat 0.200 0.125 Pass/<LOD
Spiroxamine‡ 0.400 0.125 Pass/<LOD Tebuconazole 0.400 0.125 Pass/<LOD
Thiacloprid 0.200 0.125 Pass/<LOD Thiamethoxam 0.200 0.125 Pass/<LOD
Trifloxystrobin 0.200 0.125 Pass/<LOD

* Pyrethrins are reported as the sum of Jasmolin I, Cinerin I, and Pyrethrin I
** Cyfluthrins are reported as the sum of isomers Cyfluthrin I, II, III, and IV
*** Cypermethrins are reported as the sum of isomers Cypermethrin I, II, III, and IV
**** Abamectin is reported as the sum of Avermectin B1a and Avermectin B1b
***** Spinosad is reported as the sum of Spinosyn A and Spinosyn D
† Permethrin and Prallethrin are reported as the sum of cis and trans isomers
‡ MGK-264 and Spiroximine are reported as the sum of isomers I and II
MRL - Maximum Residue Limit; LOD - Limit of Detection

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 4

IRON Laboratories

Residual Solvents Analysis by
Mass Spectrometer

Test Certificate #: 111468-001
Client Name, Sample Details

Peregrine Manufacturing
Michigan Center, MI 49254
Sample: HH Distillate
Type: Medical Flower
Method: SOP FE-44-MI

Test Conditions

Scale: XS205-MI2
Temp: 22.3 °C
Baro Pressure: 981.8 hPa
Analyst: MEH
Technician: JRT

Sample ID#: 111468

Harvest/Process Date: 09/12/2018
Serving Size (g): 1
Date Received: 09/11/2018
Test Date: 09/19/2018
Valid Through: 09/19/2019
Report Issued: 09/21/2018

Sample #111468
Compound MRL (µg/g) LOD (µg/g) Status (µg/g)   Compound MRL (µg/g) LOD (µg/g) Status (µg/g)
1,2-Dichloroethane 2 1 Pass/<LOD 1,2-Dimethoxyethane 100 5 Pass/<LOD
1,4-dioxane 380 200 Pass/<LOD 1-Butanol 5,000 100 Pass/<LOD
1-Pentanol 5,000 100 Pass/<LOD 1-Propanol 5,000 100 Pass/<LOD
2,2-Dimethylpropane (Neopentane) 5,000 100 Pass/<LOD 2,2-Dimethylbutane (Hexanes) 290 100 Pass/<LOD
2,3-Dimethylbutane (Hexanes) 290 100 Not Tested 2-Butanol 5,000 100 Pass/<LOD
2-Butanone (MEK) 5,000 50 Pass/<LOD 2-Ethoxyethanol 160 40 Pass/<LOD
2-Methylbutane (Isopentane) 5,000 50 Pass/<LOD 2-Methylpentane (Hexanes) 290 50 Pass/<LOD
2-Methylpropane (Isobutane) 5,000 50 Pass/<LOD 2-propanol (Isopropyl Alcohol) 5,000 50 Pass/<LOD
2-Propanone (Acetone) 5,000 50 Pass/<LOD 3-Methylpentane (Hexanes) 290 50 Pass/<LOD
Acetonitrile 410 100 Pass/<LOD Benzene 2 1 Pass/<LOD
Butane 5,000 50 Pass/<LOD Chloroform 1 100 Pass/<LOD
Cumene 70 35 Pass/<LOD Cyclohexane 3,880 1,000 Pass/<LOD
Dichloromethane 600 150 Pass/<LOD Dimethylsulfoxide (DMSO) 5,000 500 Pass/<LOD
Ethanol 5,000 500 Pass/<LOD Ethyl acetate 5,000 50 Pass/<LOD
Ethyl ether 5,000 500 Pass/<LOD Ethylene glycol 620 310 Pass/<LOD
Ethylene oxide 50 50 Pass/<LOD Heptane 5,000 50 Pass/<LOD
Hexane 290 50 Pass/<LOD Isopropyl acetate 5,000 50 Pass/<LOD
Methanol 3,000 500 Pass/<LOD Naptha 400 100 Pass/<LOD
N,N-Dimethylacetamide 1,090 273 Pass/<LOD N,N-Dimethylformamide (DMF) 880 500 Pass/<LOD
Pentane 5,000 50 Pass/<LOD Petroleum Ether 400 100 Pass/<LOD
Propane 5,000 50 Pass/<LOD Pyridine 200 10 Pass/<LOD
Sulfolane 200 160 Pass/<LOD Tetrahydrofuran (THF) 720 200 Pass/<LOD
Toluene 890 50 Pass/<LOD Trichloroethylene 25 6 Pass/<LOD
Xylenes* 2,170 50 Pass/<LOD

* Xylenes are reported as the sum of o-xylene, m-xylene, p-xylene, and ethylbenzene
MRL - Maximum Residue Limit; LOD - Limit of Detection

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

MEH QM Iron laboratories MEH QM

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 3 of 4

IRON Laboratories

Microbiology Analysis

Test Certificate #: 111468-001
Client Name, Sample Details

Peregrine Manufacturing
Michigan Center, MI 49254
Sample: HH Distillate
Type: Medical Flower

Test Conditions

Scale: XS205-MI2
Temp: 22.2 °C
Baro Pressure: 978.8 hPa
Analyst: ACR
Technician: ACR

Sample ID#: 111468

Harvest/Process Date: 09/12/2018
Serving Size (g): 1
Date Received: 09/11/2018
Test Date: 09/19/2018
Valid Through: 09/19/2019
Report Issued: 09/19/2018

Sample #111468
Test Method MCFU (CFU/g) LOD (CFU/g) Status (CFU/g)
Total Aerobic FE-37 10,000.0 1,000.0 Pass/<LOD
Yeast & Mold FE-37 1,000.0 1,000.0 Pass/<LOD
Bile-tolerant gram-negative bacteria FE-37 100.0 100.0 Pass/<LOD
Total Coliforms FE-37 100.0 100.0 Pass/<LOD
E. Coli FE-37 100.0 100.0 Pass/<LOD
Salmonella FE-52 100.0 100.0 Pass/<LOD
Aspergillus spp. Not Tested N/A 0.0 Not Tested

Test Method MRL (µg/g) LOD (µg/g) Status (µg/g)
Total Aflatoxin (B1, B2, G1, and G2) Not Tested 0.02 0.02 Pass/<0.02µg/g

TNTC = Too Numerous To Count. Maximum Colony Forming Units (MCFU) represents the minimum value that a test would need to achieve in order to be considered a failed result (if applicable). LOD is the Limit of Detection for the method. CFU/g = Colony Forming Units per gram. Aspergillus spp. consists of A. flavus, A. fumigatus, A. niger, and A. terreus.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

ACR - LM Iron laboratories ACR - LM

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 4 of 4