IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

Marihuana Potency Analysis by
High Performance Liquid Chromatography

Testing Accreditation #: 77802 Test Certificate #: 138001-001
Client Name, Sample Details

Unloc Gardens LLC-AU-G-C-000614
Inkster, MI 48141
Sample: Watermelon Zkittles Bud
License: AU-G-C-000614
Type: Flower
Method: FE04U12 HPLC-UV
Metrc Test Pkg#: 1A4050300025ABD000000583
Metrc Source Pkg#: 1A4050300025ABD000000579
***Water Activity: 0.49

Test Conditions

Prepsheet ID#: MIP220929A
Scale: XS205-MI2
Temp: 23.8 °C
Baro Pressure: 995.4 hPa
Analyst: SKM
Technician: KEB

Sample ID#: 138001

Harvest/Process Date: 09/28/2022
Serving Size (g): 1
Date Received: 09/28/2022
Test Date: 09/29/2022
Valid Through: 09/30/2023
Report Issued: 10/03/2022

Sample #138001
Sample #138001 Sample #138001
Test
Compounds
Δ9-THC THCA Δ8-THC CBD CBDA CBG CBGA CBN CBC CBL THCV CBDV Total
Cannabinoids*
Total THC Total CBD Calc Max Total
Cannabinoids*
Amount (%) 0.4 23.2 N/D N/D N/D 0.1 0.7 N/D N/D 0.1 N/D N/D 24.5 20.8 0.0 21.6
Amount (mg/g) 4.2 231.9 N/D N/D N/D 1.3 6.74 N/D N/D 1.2 N/D N/D 245.34 207.6 0.0 216.0
Amount per Serving (mg) 4.2 231.9 N/D N/D N/D 1.3 6.74 N/D N/D 1.2 N/D N/D 245.3 Serving Size~ (g): 1.0
LOQ (mg/g) 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.79 0.79   %Decarb. THC CBD
±%RPD 0.32% 1.47% 1.41% 3.30% 2.12% 3.81% 1.97% 1.08% 0.16% 1.02% 1.88% 1.12% 2 N/A

LOQ = Limit of Quantitation; %RPD = Relative Percent Deviation; %RSD = Relative Standard Deviation; N/D = Not Detected

*Designates values that are not currently included in the accredited scope of Iron Laboratories.

*** Designates tests that use the method FE-45. FE-45 is performed using AOAC 966.02 and 32.004-32.009.

FE-45 has relative expanded (k=2) uncertainties of 1.098% for moisture, 1.754% for water activity for unprocessed plant materials, and 13.102% for water activity for infused products.

Vitamin E acetate analysis has a relative expanded (k=2) uncertainty of 18.614%.

Total THC and CBD is the calculated sum of Δ9-THC and Δ8-THC or CBD plus the amount of THC or CBD derived from THCA or CBDA, respectively.

These values are calculated by applying a molar correction factor of 0.877 to the THCA or the CBDA value.

Calc Max Total Cannabinoids is the sum of Total THC, Total CBD, CBN, Total CBG, CBC, THCV, CBDV, and CBL.

Total CBG is calculated as CBG plus CBGA*0.878 (the molar correction factor for CBGA to CBG conversion).

%Decarb. THC and CBD refer to the percentage of Δ9-THC or CBD relative to THCA or CBDA, respectively.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

KEB - LM Iron laboratories KEB - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 1 of 2

IRON Laboratories     PJLA

ISO/IEC 17025:2017 Accredited

QC Report

Testing Accreditation #: 77802 Test Certificate #: 138001-001
Client Name, Sample Details

Unloc Gardens LLC-AU-G-C-000614
Inkster, MI 48141
Sample: Watermelon Zkittles Bud
License: AU-G-C-000614
Type: Flower
Method: FE04U12 HPLC-UV
Metrc Test Pkg#: 1A4050300025ABD000000583
Metrc Source Pkg#: 1A4050300025ABD000000579
***Water Activity: 0.49

Test Conditions

Prepsheet ID#: MIP220929A
Scale: XS205-MI2
Temp: 23.8 °C
Baro Pressure: 995.4 hPa
Analyst: SKM
Technician: KEB

Sample ID#: 138001

Harvest/Process Date: 09/28/2022
Serving Size (g): 1
Date Received: 09/28/2022
Test Date: 09/29/2022
Valid Through: 09/30/2023
Report Issued: 10/03/2022

Sample #138001
Target Compound Name Method Blank (μg/g) LCS Spike (μg/g) LCS Amount (μg/g) Percent Recovery (%) LCS LCS Duplicate Amount (μg/g) Percent Recovery (%) LCSD Relative Percent Difference (%) QC Flag
Δ9-THC 0 4.80811 4.92402 102.41 4.93971 102.74 0.32%
THCA 0 4.98446 5.08264 101.97 5.15804 103.48 1.47%
Δ8-THC 0 5.69946 5.22382 91.65 5.2979 92.95 1.41%
CBD 0 4.76637 4.99944 104.89 5.16703 108.41 3.30%
CBDA 0 4.81407 4.98945 103.64 5.09613 105.86 2.12%
CBG 0 5.34232 5.44651 101.95 5.65802 105.91 3.81%
CBGA 0 5.30119 5.43114 102.45 5.53938 104.49 1.97%
CBN 0 4.90985 4.96695 101.16 5.02108 102.27 1.08%
CBC 0 5.08835 5.3042 104.24 5.31281 104.41 0.16%
CBCA N/A 0 0 0.00 0 0.00 0%
CBL 0 5.31058 5.34556 100.66 5.29114 99.63 1.02%
THCV 0 5.07785 5.24681 103.33 5.34625 105.29 1.88%
CBDV 0 5.41538 5.22326 96.45 5.28208 97.54 1.12%

N.D. = Not Detected

LR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) Low recovery should be scrutinized for possible fail as it could indicate more compound present than is detected.

I = indicates that an amount of an interfering compound greater than the methods limit of detection was detected in the method blank sample. May indicate contamination of analytical system or consumables.

Q = indicates that the relative percent diference of two identicly prepared Matrix Spike samples for a target analyte was greater than 20%

HR = indicates compound recovery of matrix spike was outside the methods acceptable limits. (70-130%) high recoveries should be scrutinized for passing as more compound may be detected than is actually present in the sample.

Sample was sampled and tested in accordance with the Safety Compliance Facility Sampling and Testing Information.

This certificate shall not be reproduced except in full, without written approval of Iron Laboratories, LLC.

KEB - LM Iron laboratories KEB - LM

Iron Laboratories, LLC is an ISO/IEC 17025:2017 Testing Laboratory laboratory accredited by (PJLA) Perry Johnson Laboratory Accreditation, Certificate No. 77802

Tested by Iron Laboratories Michigan, 1825 E. West Maple Walled Lake, MI 48390

Page 2 of 2